TABLE OF CONTENTS Introduction ......................4 Features ....................... 4 Pre-installation ...................... 5 Installation ......................5 Operating Modes ....................6 Programming ......................7 Load Counts ....................... 10 Drain Mode ......................11 Other Features ....................12 Troubleshooting ....................15 System Wiring Diagram ..................16 System Parts Diagram ..................
Page 3
QUICK-START PROGRAMMING The steps below will give you just the basics to quickly setup a new system — more details and complete programming information are included in the following pages of this manual. (1) Press once (for default 000 access code). (2) Press ENTER...―ACC‖...
INTRODUCTION FEATURES The On-Premise Pro was designed to meet today’s 8 formula capability for various soil conditions laundry chemical injection needs with economy and Independent pump run times to provide specific flexibility in mind. Advanced microprocessor technology volume injections makes the OP-Pro one of Knight’s least expensive ...
PRE-INSTALLATION Before the equipment is installed, you should survey the (7) For each pump, cut the discharge tube to length installation site thoroughly. At the very least, your survey and insert one end into the right (output) side of the should include the following: pump’s squeeze tube.
OPERATING MODES Normal operation: Relay mode: The system is capable of 8 user selectable formulas The intended use of relay mode is for machines that are with each formula having unique run times and delay microprocessor controlled. The pumps run for as long times for each pump.
PROGRAMMING Before programming, please read the following Entering the access code: important notes. Do not access the system while pumps are being signaled from the washer. Use whichever of the The access code must be entered to program, prime following two procedures that applies.
Page 8
(4) Choose the desired pump and formula using their Priming the pumps: respective SELECT buttons. (1) Enter the access code if you do not already have (5) Position your container below the output of the access to the system. pump you selected, then press CALIBRATE. The (2) Ensure that the pump time LED is flashing.
Page 9
NOTE: During delay time countdown - will display Selecting delay time units: indicating a countdown in one minute increments. If Pump delay times can be set in one second increments programmed to delay in one second increments, the for 0 - 255 seconds, or one minute increments for 0 - 99 display will count down from the delay time to zero.
LOAD COUNTS The load count pump of the On-Premise Pro performs a To view/clear formula load counts: number of important functions. Entering the access code is not required for this function. This allows laundry room managers or Counts the loads for all formulas used operators to check load counts, and reset them at the ...
DRAIN MODE Drain mode counts the number of times the drain Assigning drain numbers: solenoid is energized during the machine’s operating (1) Enter the access code if you do not already have cycle, and chemicals are injected by their programmed access to the system.
OTHER FEATURES Setting signal lockout time: Level enable/disable: Signal lockout is an optional feature that can be used to This feature allows you to disable or ―over-ride‖ the prevent unwanted injections when unwanted supply second level injection sequence used in normal signals are received multiple times during a washcycle.
Page 13
System reset timer: Formula enable/disable: The system can be programmed to delay the reset for This feature allows you to choose only those formula up to 75 minutes after the load count pump starts. This numbers that you want visible to the operator for is useful where the system may receive extra signals in selecting the chemical formula from the On-Premise Pro the final rinse or extract cycles (common on smaller...
Page 14
Auto formula select time: Auto formula select mode: The auto formula select time is used with micro mode to MICRO: For use with microprocessor controlled establish a time ―increment‖ for selecting formulas. The washers that can send a signal of exact duration to the signal duration will be divided by the number selected to unit.
TROUBLESHOOTING Remote control does not light up - power Flush errors keep occurring: indicator does not come on: Check to see if a flush manifold is used — if so, is it operating correctly? Check fuse on circuit board inside dispenser — replace if necessary.
The information and specifications included in this publication were in effect at the time of approval for printing. Knight LLC reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatsoever. KNIGHT LLC, A Unit of IDEX Corporation (www.knightequip.com) Knight Headquarters USA Toll Free Knight Canada...