Advertisement

On-Premise Pro
Instruction Manual
0901133 Rev: A (11/13)
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Idex Knight On-Premise Pro

  • Page 1 On-Premise Pro Instruction Manual 0901133 Rev: A (11/13) Page 1 of 20...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction ......................4 Features ....................... 4 Pre-installation ...................... 5 Installation ......................5 Operating Modes ....................6 Programming ......................7 Load Counts ....................... 10 Drain Mode ......................11 Other Features ....................12 Troubleshooting ....................15 System Wiring Diagram ..................16 System Parts Diagram ..................
  • Page 3 QUICK-START PROGRAMMING The steps below will give you just the basics to quickly setup a new system — more details and complete programming information are included in the following pages of this manual. (1) Press  once (for default 000 access code). (2) Press ENTER...―ACC‖...
  • Page 4: Introduction

    INTRODUCTION FEATURES The On-Premise Pro was designed to meet today’s  8 formula capability for various soil conditions laundry chemical injection needs with economy and  Independent pump run times to provide specific flexibility in mind. Advanced microprocessor technology volume injections makes the OP-Pro one of Knight’s least expensive ...
  • Page 5: Pre-Installation

    PRE-INSTALLATION Before the equipment is installed, you should survey the (7) For each pump, cut the discharge tube to length installation site thoroughly. At the very least, your survey and insert one end into the right (output) side of the should include the following: pump’s squeeze tube.
  • Page 6: Operating Modes

    OPERATING MODES Normal operation: Relay mode: The system is capable of 8 user selectable formulas The intended use of relay mode is for machines that are with each formula having unique run times and delay microprocessor controlled. The pumps run for as long times for each pump.
  • Page 7: Programming

    PROGRAMMING Before programming, please read the following Entering the access code: important notes. Do not access the system while pumps are being  signaled from the washer. Use whichever of the The access code must be entered to program, prime following two procedures that applies.
  • Page 8 (4) Choose the desired pump and formula using their Priming the pumps: respective SELECT buttons. (1) Enter the access code if you do not already have (5) Position your container below the output of the access to the system. pump you selected, then press CALIBRATE. The (2) Ensure that the pump time LED is flashing.
  • Page 9 NOTE: During delay time countdown - will display Selecting delay time units: indicating a countdown in one minute increments. If Pump delay times can be set in one second increments programmed to delay in one second increments, the for 0 - 255 seconds, or one minute increments for 0 - 99 display will count down from the delay time to zero.
  • Page 10: Load Counts

    LOAD COUNTS The load count pump of the On-Premise Pro performs a To view/clear formula load counts: number of important functions. Entering the access code is not required for this  function. This allows laundry room managers or Counts the loads for all formulas used operators to check load counts, and reset them at the ...
  • Page 11: Drain Mode

    DRAIN MODE Drain mode counts the number of times the drain Assigning drain numbers: solenoid is energized during the machine’s operating (1) Enter the access code if you do not already have cycle, and chemicals are injected by their programmed access to the system.
  • Page 12: Other Features

    OTHER FEATURES Setting signal lockout time: Level enable/disable: Signal lockout is an optional feature that can be used to This feature allows you to disable or ―over-ride‖ the prevent unwanted injections when unwanted supply second level injection sequence used in normal signals are received multiple times during a washcycle.
  • Page 13 System reset timer: Formula enable/disable: The system can be programmed to delay the reset for This feature allows you to choose only those formula up to 75 minutes after the load count pump starts. This numbers that you want visible to the operator for is useful where the system may receive extra signals in selecting the chemical formula from the On-Premise Pro the final rinse or extract cycles (common on smaller...
  • Page 14 Auto formula select time: Auto formula select mode: The auto formula select time is used with micro mode to MICRO: For use with microprocessor controlled establish a time ―increment‖ for selecting formulas. The washers that can send a signal of exact duration to the signal duration will be divided by the number selected to unit.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Remote control does not light up - power Flush errors keep occurring: indicator does not come on:  Check to see if a flush manifold is used — if so, is it  operating correctly? Check fuse on circuit board inside dispenser — replace if necessary.
  • Page 16: System Wiring Diagram

    SYSTEM WIRING DIAGRAM Page 16 of 20 0901133 Rev: A (11/13)
  • Page 17: System Parts Diagram

    SYSTEM PARTS DIAGRAM 0901133 Rev: A (11/13) Page 17 of 20...
  • Page 18 SYSTEM PARTS DIAGRAM Page 18 of 20 0901133 Rev: A (11/13)
  • Page 19: Conformity Documentation

    0901133 Rev: A (11/13) Page 19 of 20...
  • Page 20: Warranty Information

    The information and specifications included in this publication were in effect at the time of approval for printing. Knight LLC reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatsoever. KNIGHT LLC, A Unit of IDEX Corporation (www.knightequip.com) Knight Headquarters USA Toll Free Knight Canada...