LOAD COUNTS

The load count pump of the On-Premise Pro performs a
number of important functions.
Counts the loads for all formulas used
Terminates signal lockout time
Resets ―levels‖ for pumps 1 - 6 (the selected load
count pump can only have 1 wash level)
Starts the system reset timer
Select the last pump that will receive a signal during any
wash formula. The load count pump must receive a
signal at the end of each formula. A signal should be
received even if the pump will not dispense chemical for
the selected formula.
Choosing the proper load count pump is critical when
using Drain Mode to maintain proper injection
sequence. When drain mode is enabled, the load count
pump will default to pump #7. This can be changed to a
different pump number, if desired. Normally you will set
the load count pump to correspond with the last drain
signal that will be received during the formula, however
there may be additional drain signals that occur after the
last pump has injected. See the Drain Mode section for
more details.
Setting the load count pump:
(1) Enter the access code if you do not already have
access to the system.
(2) Press ENTER twice. The pump time and delay time
LEDs will be off and the current load count pump
will be displayed in the pump window for a few
seconds. If the pump time and delay time LEDs are
not off, repeat this step.
(3) Use PUMP SELECT to choose the load count
pump number. Do not use pump A through F. The
display will ―flash while you are selecting the load
count pump (this is normal).
(4) After a few seconds the pump time LED will return,
indicating the pump number was accepted.
(5) If the pump time LED returns before the desired
pump has been chosen, repeat steps 2 & 3.
Page 10 of 20
To view/clear formula load counts:
Entering the access code is not required for this
function. This allows laundry room managers or
operators to check load counts, and reset them at the
interval of their choosing, without the possibility of
changing pump programming.
The following steps are for normal operation only.
(1) Press ENTER. The pump time and delay time LEDs
will be off, and the load count will be shown on the
3-digit display for the current formula number.
(2) Use FORMULA SELECT to view load counts for
other formulas while the pump time and delay time
LEDs are off (formula 0 shows a cumulative total
for all formulas).
(3) After a few seconds, the display will flash and
return to its previous appearance.
(4) To clear formula load counts, press  while the
count is being shown until 000 appears on the 3-
digit display. Do this for all formulas, including
formula 0. If the display flashes before the count
was cleared, repeat this step.
The following steps are for drain mode only.
(1) Use FORMULA SELECT until desired formula
number is displayed.
(2) Press ENTER. The pump time and delay time LEDs
will be off, and the load count will be shown on the
3-digit display for the current formula number.
(3) After a few seconds, the display will flash and
return to its previous appearance. Repeat steps 1 &
2 for all formulas you wish to view.
(4) To clear the formula load count, press  while the
count is being shown until 000 appears on the 3-
digit display. Do this for all formulas. If the display
flashes before the count was cleared, repeat this
step.