TROUBLESHOOTING

Remote control does not light up - power
indicator does not come on:
Check fuse on circuit board inside dispenser —
replace if necessary.
Check voltage at power input terminals inside
dispenser — refer to wiring diagram.
Pumps do not trigger from signals:
Check signal voltage and duration.
Check for flush error — press RESET to clear.
Check pump run and delay time settings.
Pump may be counting down a "lockout" time (if used)
from a previous activation.
Pump may be trying to activate its "second level"
feature (this applies to pumps 1 - 6 only).
System may be set for Drain Mode, which requires
pumps to have a drain number assignment to
activate.
Pumps will not turn when trying to prime, or
during a washcycle:
Check for loose pump motor wires.
Check for voltage from circuit board to motor.
Check for mechanical binding of moving parts.
0901133 Rev: A (11/13)
Flush errors keep occurring:
Check to see if a flush manifold is used — if so, is it
operating correctly?
Check flow switch for proper connection to dispenser
and proper water flow. Jumper JP1 should be set if a
flow switch is not used.
Press RESET to clear flush errors — pumps will not
run during flush error.
Pumps run but do not dispense product:
Check product containers.
Check squeeze tube for wear.
Check condition of roller and pump housing.
Check for air leaks on suction line.
Check for blockage from pump tube into flush
manifold (if used).
Pumps trigger more than once during cycle:
Check supply signal input for repeat signals from
washmachine.
Check signal lock-out function.
If drain mode is used, verify if a second level is
programmed.
All pumps run at the same time.
Check signals from washmachine.
May be using relay mode with drain mode enabled.