10 Technical data
R1H (A2P)
* Humidity sensor
R1T (A1P )
Outlet water heat exchanger thermistor
R1T (A2P)
* Ambient sensor On/OFF thermostat
R1T (A14P)
* Ambient sensor user interface
R2T (A1P)
Outlet backup heater thermistor
R2T (A2P)
* External sensor (floor or ambient)
R3T
Refrigerant liquid side thermistor
R4T
Inlet water thermistor
R5T, R8T
Domestic hot water thermistor
R6T
* External indoor or outdoor ambient
thermistor
R7T
Mixed leaving water thermistor
S1S
# Preferential kWh rate power supply contact
S2S
# Electrical meter pulse input 1
S3S
# Electrical meter pulse input 2
S4S
# Smart grid feed-in
S6S~S9S
* Digital power limitation inputs
S10S-S11S
# Low voltage Smart grid contact
SS1 (A4P)
* Selector switch
SW1+SW2
Turn buttons
(A12P)
SW3~SW5
Push buttons
(A12P)
TR1
Power supply transformer
X6M
# Backup heater power supply terminal strip
X10M
* Smart grid power supply terminal strip
X*, X*A, X*Y, Y*
Connector
X*M
Terminal strip
* Optional
# Field supply
Translation of text on wiring diagram
English
(1) Main power connection
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Indoor unit supplied from outdoor
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Electrical connection diagram
For more details, please check the unit wiring.
Installation manual
38
Translation
(1) Main power connection
For preferential kWh rate power
supply
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Switch box
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
English
Only for LAN adapter
Only for remote user interface
(5) Ext. thermistor
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Translation
Only for the LAN adapter
Only for the user interface used
as room thermostat
(5) External thermistor
Switch box
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous current
Domestic hot water pump output
Domestic hot water pump
Electrical meters
For safety thermostat
Inrush current
Maximum load
Normally closed
Normally open
Safety thermostat contact:
16 V DC detection (voltage
supplied by PCB)
Shut-off valve
Switch box
(7) Option PCBs
Alarm output
Changeover to external heat
source
Maximum load
Minimum load
Only for demand PCB option
Only for digital I/O PCB option
Options: external heat source
output, alarm output
Options: On/OFF output
Power limitation digital inputs:
12 V DC / 12 mA detection
(voltage supplied by PCB)
Space cooling/heating On/OFF
output
Switch box
(8) External On/OFF thermostats
and heat pump convector
Additional leaving water
temperature zone
Main leaving water temperature
zone
Only for external sensor (floor or
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629092-1A – 2020.08