Daikin Altherma 3 R F Installation Manual page 15

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

A
B
a
A
B
X1M
1 2 3
X11YA
X11Y
X1A
a
Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
Interconnection
Wires: (3+GND)×1.5 mm²
cable (= main
power supply)
Normal kWh rate
Wires: 1N
power supply
Maximum running current: 6.3 A
Preferential kWh
Wires: 2×(0.75~1.25 mm²)
rate power supply
Maximum length: 50 m.
contact
Preferential kWh rate power supply
contact: 16 V DC detection (voltage
supplied by PCB). The voltage-free
contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
[9.8] Benefit kWh power supply
Connect X11Y to X11YB.
EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629092-1A – 2020.08
1 2 3
a
X11YB
X2M
1 2 3
a
A
B
a
A
B
X1M
1 2 3
X11YA
X1A
a
Interconnection cable (=main power supply)
b
Normal kWh rate power supply
c
Preferential power supply contact
3 Fix the cables with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect
X11Y to X11YB. The necessity of separate normal kWh
rate power supply to indoor unit (b) X2M/5+6 depends on
the type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪ if preferential kWh rate power supply is interrupted
when active, OR
▪ if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/9+10) as the safety
thermostat.
Thus,
the
preferential kWh rate power supply OR a safety
thermostat.
6 Electrical installation
1N~, 50 Hz,
230 V AC, 6.3 A
S1S
L
N
6
5
9
10
b
c
b
c
5 6
X2M
X11YB
9 10
X11Y
X5M
system
can
have
EITHER
Installation manual