NuAire SLIMAIRE Installation Manual page 3

12v & 230v, continuous 2 speed slimline axial fans

Advertisement

Installation Manual
Unit Codes
m³/hr
NA / SLIMAIRE 100X
95
NA / SLIMAIRE 150X
280
4.0 ELECTRICAL INSTALLATION
4.1 Electrical Information
IMPORTANT
Isolation - Before commencing work make sure that the
unit is electrically isolated from the mains and switched live
supply.
It is recommended that the installation be carried out by a qualified
electrician. All electrical connections must comply with current IEE
wiring regulations. The fan is a fixed appliance, and the electrical supply
must therefore be by a fixed wired and fused (3 amp) spur incorporating
a double or triple pole switch with contact openings of at least 3mm.
Use twin conductor cable of at least 1mm3 in section (Figure 9).
The fan is double insulated and does not require earthing. The fan
complies with current electrical safety regulations (IE64, CENELEC
384), including EEC Directive EMC2004/108/CE concerning the
suppression of radio interference and electromagnetic compatibility,
and LVD2006/95/CE.
The fan must not be used as a switch for water heaters, stoves etc.
The printed circuit board in these fans has been protected to make it
compatible with the majority of fluorescent fittings available on the
market today. However, it is impossible to be aware of all new products
introduced. We suggest, therefore, that you contact your supplier to
establish the compatibility of any fluorescent fittings you intend to use.
4.2 Wiring diagrams
4.2.1 SLIMAIRE/NA 100XPC/150XPC with Integral Cord
2
Wiring - SLIMAIRE/NA 100XPC/150XPC
L
N
Double Pole Isolator
4.2.2 SLIMAIRE/NA 100XPC/150XPC
3
Wiring - SLIMAIRE/NA 100XPC/150XPC
N
T
L
Triple Pole Isolator
Nuaire |
Western Industrial Estate
Pa
W
dBA @ 3m
27
11
40
320
26
49
~
L
230V
50Hz
N
~
N
230V
50Hz
L
|
|
| nuaire.co.uk
Caerphilly
CF83 1NA
4.2.3 SLIMAIRE/NA 100XPC-12 with Integral Cord
4
Wiring - SLIMAIRE/NA 100XPC-12
L
N
12V
L
N
Fan Unit
4.2.4 SLIMAIRE/NA 100HT/100PIR/150HT/150PIR with
Humidistat and Integral Sensor Only
5
Wiring - SLIMAIRE/NA 100XPC-12
L
N
12V
230V
L
N
T
Fan unit
20. 03. 20. Document Number 671421
SLIMAIRE / NA XPC
Transformer
L
N
230V
~
230V
50Hz
N
L
Double Pole Isolator
Transformer
L
N
~
230V
50Hz
Triple Pole Isolator
N
L
3