1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•Read these instructions completely and thoroughly before
working with the product.
•Keep these instructions in a location where they are accessible
to all users at all times.
•Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•Protective Steel Toed Shoes - when handling heavy objects.
•Full Finger Gloves (Marigold PU800 or equivalent) - when
handling sheet metal components.
•Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•Safety Glasses - when conducting any cleaning/cutting operation
or exchanging filters.
•Reusable Half Mask Respirators - when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
These IPX4-Splashproof fans have been specifically designed to
ventilate small rooms such as toilets, bathrooms, cloakrooms and
kitchens etc. and can be installed on wall, ceiling or panel.
The units extract directly to outside or through a short length of
ducting.
Unit Codes
4" Axial continuous low duty with
NA100XPC /
boost facility via pull cord / remote
SLIMAIREX100PC
switch operation.
12V version of 4" Axial continuous
NA100XPC-12 /
low duty with boost facility via pull
SLIMAIRE100XPC-12
cord / remote switch operation.
6" Axial continuous low duty with
NA150XPC /
boost facility via pull cord / remote
SLIMAIREX150PC
switch operation.
3.0 MECHANICAL INSTALLATION
Installation must be completed by competent persons, in accordance
with good industry practice and should conform to all governing and
statutory bodies i.e. IEE, CIBSE, etc.
This product should not be used in an ambient temperature higher than
40°C (104°F) and should not be exposed to atmospheric agents (rain,
sun, snow, etc.). The product or any part of it should not be placed in
water or other liquids.
Nuaire |
Western Industrial Estate
Weight
Operation Type
|
|
| nuaire.co.uk
Caerphilly
CF83 1NA
1
Unit Components
1
3.1 Component Key
1. Front Fixing Screw
2. Front Grille
3. Front Cover
4. Motor Fan Assembly
3.2 Surface Mounting
Remove the fan from the box, taking care to dispose of the packing
material properly. Check the location of existing wiring for ease of
connection. For optimum performance site the fan a minimum of 2.3m
above ground level.
In the wall or ceiling, cut a hole as follows:
•SLIMAIRE / NA 100X fans - 100mm Ø (taking care to allow any
necessary space for ducting).
•SLIMAIRE / NA 150X fans - 150mm Ø - for through wall
installation.
•SLIMAIRE / NA 150X fans - 156mm Ø - for installation using a wall
liner or telescopic ducting.
For any other wall or ceiling installation check sizes before cutting the
hole. It is the installer's responsibility to use the appropriate core
cutter to obtain the correct hole diameter.
Dismantle the fan:
•Remove the front cover (3) by unscrewing front fixing screw (1).
(Kg)
•Using the motor fan assembly (4) of the fan as a template, mark
the hole drilling positions to fix the fan to the wall or ceiling N.B
1.5
use the holes already knocked out in the top right and bottom left
corners of the back of the motor fan assembly.
•Drill the 6mm dia holes.
0.5
•Using the wall plugs and long screws provided, fix the motor fan
assembly (4) to the wall/ceiling.
1.5
Before fixing the fan to the wall, decide whether to have the cable
entering the fan through the knocked-out hole on the top of the
motor fan assembly (4) or whether through the back of the motor fan
assembly (4). In the first case the included cable clamp will need to be
used. In the second option the cable entry hole will need to be knocked
out.
Connect to electricity supply via a double pole switch of a suitable size,
with contact openings of at least 3mm.
Fix back the front cover (3) of the fan.
For window installation (with optional window kit) see instructions on
page 2.
20. 03. 20. Document Number 671421
SLIMAIRE / NA XPC
8
7
4
2
3
5. Wall Fixing Screws
6. Wall Plug
7. Cable Clamp Screws
8. Cable Clamp
9. Cable Grommet
6mm dia.
6
5
2

Advertisement

loading

This manual is also suitable for: