Specifications - Omron H7BR Series Manual

Digital counter
Hide thumbs Also See for H7BR Series:
Table of Contents

Advertisement

H7BR

Specifications

Model
Classification
Digital preset counter
Mounting method
Flush mounting
External connections
Screw terminals
Enclosure ratings
IP54 (panel surface)
Approved standards
UL508, CSA C22.2 No.14, conforms to EN61010-1/IEC61010-1, EN50081-2, and EN50082-2
Input modes*
Up (Incrementing), Down (decrementing), and
reversible
Up/Down A (command inputs),
Up/Down B (individual inputs),
Up/Down C (quadrature inputs)
Output modes*
N, F, C, R, K, P, Q, A
Reset system
External, manual and automatic resets (internal
according to C, R, P, AND Q mode operation)
Prescaling function
Yes (0.001 to 99.999)
Decimal point
Yes (Rightmost 3 digits)
adjustment
Teaching function
---
Batch counting function
Yes
Set compensation
---
Gate input
Yes
Sensor power supply
12 VDC/24 VDC (switching)
Input signals
Count, reset, key protection, and gate inputs
Batch count reset input
Input method
No-voltage input: Via opening and closing of contact
Voltage input:
Control outputs
1 stage model: SPST-NO contact and transistor (NPN or PNP open collector) output
2 stage model: 2 stages of SPST-NO contact and transistor (NPN or PNP open collector) output
Transistor output can be changed by switch. (Except for batch count output.)
Batch outputs
Transistor output (NPN or PNP open collector)
Display
LCD with backlight
Digits
6 digits (0 to 999,999)
Memory backup
Backup time for power interruption: Approx. 10 years at 20°C (lithium battery)
H7BR-B (Standard type)
Via high and low signal voltage (key protection is no-voltage input)
H7BR-C (±Range type)
Reversible
Up/Down A (command inputs),
Up/Down B (individual inputs),
Up/Down C (quadrature inputs)
K, D, L, H
External and manual resets
Yes
---
Yes
Compensation input
---
±6 digits (-999,999 to 999,999)
H7BR
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H7br-bH7br-c

Table of Contents