Troubleshooting - Sharp KC-F32EU Operation Manual

Air purifier with humidifying function
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

TROUBLESHOOTING

TROUBLESHOOTING
Before calling for service, review the troubleshooting chart below to make sure that the
problem is not a unit malfunction.
SYMPTOM
Odour and smoke persists.
The Dust Sign light is green even
when the air is not clean.
The Dust Sign light is orange or red
even when the air is clean.
The unit makes a clicking or ticking
sound.
Air discharged from the unit has an
odour.
The unit does not operate when
cigarette smoke is in the air.
The Filter Indicator Light is on.
The Dust Sign lights are turned off.
The Humidify Light does not light off
when the Humidifying Tray is empty.
The water level in the Humidifying
Tray does not decrease or decreases
slowly.
The Dust Sign lights change colour
frequently.
There is a discrepancy between the
unit's Humidity Monitor and another
hygrometer in the room.
ERROR DISPLAY
DIGITAL
INDICATION
Fan motor error.
Temperature-humidity sensor error.
KC-F32EU_OM_WEST.indb 18
REMEDY (the following are not due to a malfunction)
• Check the filters. If they appear to be extremely dirty, clean or
replace them. (Ref. E-13,E-14,E-15,E-16,E-17)
• The air may have been dirty when the unit was plugged in. Unplug
the unit, wait one minute, and then plug the unit in again.
• Dirty or clogged dust sensor openings interfere with sensor
operation. Gently clean the back panel. (Ref. E-13).
• The unit may make clicking or ticking sounds when it is generating
ions.
• Check to see if the filters are extremely dirty.
• Clean or replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone that can
produce an odour.
• Check to see if the unit is installed in a location that makes it
difficult for the sensors to detect cigarette smoke.
• Check to see if the dust sensor openings are blocked or clogged.
If they are blocked or clogged, clean the back panel. (Ref. E-13)
• Whenever replacing the filters, connect the power cord to an outlet
and then press the Filter Reset Button.
• Check to see if the Lights OFF Mode is selected. If it is selected,
press the Light ON/OFF Button to turn the indicator lights on.
(Ref. E-11)
• Check to see if the SLEEP mode is selected. (Ref. E-10)
• Clean the Humidifying Tray. Make sure that the unit is on a level
surface.
• Check to see if the Humidifying Tray is correctly installed. Check
the Humidifying Filter.
• If the Humidifying Filter is extremely dirty, clean or replace it.
(Ref. E-14, E-15, E-17).
• Humidification amount gets lower when humidity reaches to the
proper amount (55 ~ 65%) by the actuation of humidity sensor in
the case of fan speed automatic.
• The Dust Sign lights automatically change colour when the dust
sensor detect impurities.
• There is a difference in the humidity level within the same room.
• The sensor have different measurement parameters.
• If the monitor indicates TEMPERATURE, press the Display Select
Button. (Ref. E-11)
If the error continues to occur, contact a Sharp Service Centre.
ERROR DETAILS
E-18
REMEDY
Unplug the unit, wait one minute, then plug the unit
in again.
2017-09-28 08:58:23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kcf32euw

Table of Contents