เครื ่ อ งฟอกอากาศพร อ มไอนํ ้ า AIR PURIFIER with Humidifying Function “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. OPERATION MANUAL *The number in this technology mark indicates the approximate number of ions supplied into 1 of air, which is measured around the center of a room (with the “High-Density Plasmacluster...
Page 20
Before operating your new air purifi er, please read the following The air purifi er draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the unit, and then discharges it through the air outlet.
Page 21
Sensor technology continuously monitors air quality and automatically adjusts operation based on air purity and humidity level. Thank you for purchasing this SHARP Air Purifi er. Please read this manual carefully before using the air purifi er. After reading, keep the manual in a convenient location for future reference.
Page 22
Sharp authorized Service Center or a similarly qualifi ed service provider. • Only a Sharp Authorized Service Center should service this air purifi er. Contact the nearest Service Center for any problems, adjustments, or repairs. •...
CAUTIONS CONCERNING OPERATION • Do not operate the unit without the fi lters and the Humidifying Tray properly installed. • Keep the unit away from water. • Do not wash and reuse the HEPA fi lter and Deodorizing fi lter. Doing so will not improve fi...
Page 24
PART NAMES FRONT / BACK FRONT BACK (Plug shape varies by country.) Operation Panel / Display (Ref.E-5) Humidifying Tray Handle (2 Locations) Float Main Unit HEPA Filter Air Outlet Deodorizing Fiter Filter Frame Senser (internal) Humidifying Filter Back Panel (Pre-Filter) Float (in Filter Frame) Air lnlet Tray Handle...
Page 25
OPERATION PANEL / DISPLAY CLEAN SHOWER Display Dust Sign Indicates the air purify level 3 colors. Clean Green Orange Impure Humidify Light Humidity / Temperature monitor Green....Humidify ON Indicates the approximate humidity / temperature level in the room. Green....Unit needs water temperature 0 to 50ºC is displayed at 1ºC-intervals (Flashing) Off ......
PREPARATION Always be sure to remove the power plug from the wall outlet. FILTER INSTALLATION Remove the Back Panel. Back Panel HEPA filter Deodorizing filter Remove the Filters from the plastic bag. Place the surface with tag. Install the Filters in the correct order as shown.
REFILLING THE HUMIDIFYING TRAY Humidify air passed through by vaporizing water pumped up from Humidifying Tray. The unit can be used even without water in the Humidifying Tray. Pull out the Humidifying Tray CAUTION Clean the Humidifying Tray if it becomes dirty or there is a noticeable odor.
OPERATION Power ON / OFF • Select the desired fan speed by START STOP • Unless the power cord has been unplugged, the operation starts in the previous mode it was operated in. CLEAN ION SHOWER Releases high-density Plasmacluster ions and discharges strong air fl ow for 60 minutes. START NOTE •...
Page 29
USEFUL FUNCTION LIGHT CONTROL You can set the front surface Indicators to OFF when the Indicator is too bright. Press Press more than 3 more than 3 seconds. seconds. Plasmacluster Ion ON/OFF When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light is on. (blue) NOTE Press Press...
Page 30
USEFUL FUNCTION Off TIMER Select the length of time you want. The unit automatically stops once the selected time is reached. 1 hour 2 hours 4 hours 8 hours CANCELLATION NOTE • Pressing displays the remaining time. • To reset the operating time, press while the remaining time is being displayed.
CARE AND MAINTENANCE FILTER INDICATOR The filter Indicator Light will turn After performing on after approximately 720 hours. maintenance, reset (30 days × 24 hours =720 hours) the Filter Indicator. This is a reminder to perform the maintenance described below. (Ref.E-11,E-12,E-13,E-14) Press more than 3 seconds.
Page 32
CARE AND MAINTENANCE HUMIDIFYING FILTER / TRAY Odor occurrence may be suppressed when washing Humidifying Filter and Humidifying Tray with water carefully even if the Filter Indicator Light is not ON. Remove the Humidifying Filter from the Tray. Turn down Remove Pull up Open...
Page 33
Always be sure to remove the power plug from the wall outlet. NOTE How to remove the water scale Recommended descaling solutions CAUTION <with citric acid> <with lemon juice> NOTE How to clean the Humidifying Tray and the Filter Frame when overly dirty After maintenance, correctly reattach the parts.
CARE AND MAINTENANCE CARE AND MAINTENANCE Wipe with a dry, soft cloth. UNIT CAUTION • Do not use volatile fluids. Benzene paint thinner or polishing powder can damage the surface. • Do not use detergents. Detergent ingredients can damage the unit. CLEANING FILTERS Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment.
Filter : 1 unit Filter : 1 unit FZ-F30HFE FZ-F30DFE FZ-F30MFE KC-F30TA NOTE Use the date label to remind you when to replace the filter. There is the date label on the left side of the unit. Do not throw away...
Page 36
Humidity Monitor and another • If the monitor indicates TEMPERATURE, press the Display Select hygrometer in the room. Button. (Ref. E-9) ERROR DISPLAY If the error continues to occur, contact a Sharp Service Center. DIGITAL ERROR DETAILS REMEDY INDICATION Fan motor error.
Page 37
SPECIFICATIONS 220V 50Hz Power supply Fan Speed Adjustment SLEEP Fan Speed (m /hour) CLEAN AIR Rated Power (W) Noise Level (dBA) Fan Speed (m /hour) Rated Power (W) CLEAN AIR &HUMIDIFY Noise Level (dBA) Humidifi cation (mL/hour)*1 Recommended Room Size (m High density Plasmacluster ion recommended room size (m Humidifying Tray Capacity (L) Sensors...
Page 38
Memo OM_KC-F30TA_EN.indd E-18 OM_KC-F30TA_EN.indd E-18 4/7/2559 BE 11:04 AM 4/7/2559 BE 11:04 AM...
Page 39
Memo OM_KC-F30TA_EN.indd E-19 OM_KC-F30TA_EN.indd E-19 4/7/2559 BE 11:04 AM 4/7/2559 BE 11:04 AM...
Page 40
FACTORY USE ONLY Printed in China TINS-A879KKRZ OM_KC-F30TA_EN.indd E-20 OM_KC-F30TA_EN.indd E-20 4/7/2559 BE 11:04 AM 4/7/2559 BE 11:04 AM...