Page 2
Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
Periodic test ........................... Adjustment ..........................Operation ..........................Normal mode ..........................Error display..........................Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Supplementary data ......................Radio approval.......................... Order reference ........................System ............................Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
Page 4
Contents Accessories ..........................EC declaration of conformity ....................Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
PSEN cs5.13 M12/8 EX Introduction Validity of documentation This documentation is valid for the product PSEN cs5.13 M12/8 EX from Version 2.0. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
Are familiar with the basic regulations concerning health and safety / accident prevention, Have read and understood the information provided in the section entitled Safety Have a good knowledge of the generic and specialist standards applicable to the specific application. Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
– Make sure that the cable separators/connectors are used only within the potentially explosive area. The IP protection type (see Technical details [ 32]) has been determined in accord- ance with DIN EN 60529 with a safety switch that is as new. Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
Electrical states of the safety inputs and outputs (when switch is ready for operation: DEVICE LED is green): Actuator in Safety input Safety input Safety out- Safety out- Signal out- the re- put 12 put 22 put Y32 sponse range High High High High High High Operating Manual PSEN cs5.13 M12/8 EX 22218-EN-04...
Page 10
The status of the actuator is output. If a fieldbus module of the SDD is used, the signal output/diagnostic output for the writing of data is activated. Block diagram A1 A2 S11 S21 SDD Input Power Input Receiver Actuator SDD Output 12 22 Operating Manual PSEN cs5.13 M12/8 EX | 10 22218-EN-04...
36]) to connect several sensors with only one cable from the field in the control cabinet. Further information on Safety Device Diagnostics can be found in Additional documents that apply [ Operating Manual PSEN cs5.13 M12/8 EX | 11 22218-EN-04...
Typical release distance: 14 mm [2] Actuator aligned to the triangle marking on the switch Assured operating distance: 4 mm Assured release distance: 12 mm Typical operating distance: 5 mm Typical release distance: 8 mm Operating Manual PSEN cs5.13 M12/8 EX | 12 22218-EN-04...
Lateral offset when aligning to the triangle or square marking Alignment 1: Actuator aligned to the square Alignment 2: Actuator aligned to the triangle marking on the switch marking on the switch -8 -4 0 -12 -8 -4 0 Operating Manual PSEN cs5.13 M12/8 EX | 13 22218-EN-04...
Page 14
[1] Hysteresis [2] Typical operating distance S [3] Typical release distance S [4] Offset in mm [5] Operating distance in mm [6] Response range [7] Status of LED [8] Square marking Operating Manual PSEN cs5.13 M12/8 EX | 14 22218-EN-04...
Page 15
[8] Limit of response range, position of gate hinge [9] Status of LED [10] Sensing face of the actuator, labelled with Pilz logo [11] Distance from the front edge of the sensor to the limit of the response range (position if the gate end stop) = 15.9 mm...
The power supply must meet the regulations for extra low voltages with protective separ- ation (SELV, PELV). The inputs and outputs of the safety switch must have a protective separation to voltages over 60 VDC. Operating Manual PSEN cs5.13 M12/8 EX | 16 22218-EN-04...
Page 17
Output, channel2 yellow Signal output/diagnostic output grey Input, channel 1 pink 0 V UB blue Diagnostics input The wire colour also applies for the cable available from Pilz as an accessory. Operating Manual PSEN cs5.13 M12/8 EX | 17 22218-EN-04...
Also note the max. current (see Technical details [ 32]). Connection diagram, single connection without SDD Actuator Safety switch Ex area Non-Ex area Evaluation device Operating Manual PSEN cs5.13 M12/8 EX | 18 22218-EN-04...
Page 19
(e.g. PL e (Cat. 4)), the maximum delay or risk time permitted by the application. Ensure there is sufficient supply voltage, taking inrush currents and fusing into considera- tion. Operating Manual PSEN cs5.13 M12/8 EX | 19 22218-EN-04...
Page 20
– PSEN ix2 F4 code – PSEN ix2 F8 code – PSEN Y junction M8-M12/M12 PIGTAIL – PSEN Y junction M12-M12/M12 PIGTAIL – PSEN Y junction M12 SENSOR – PSEN Y junction M12 cable channel Operating Manual PSEN cs5.13 M12/8 EX | 20 22218-EN-04...
Page 21
Connection diagram, series connection without SDD 24 V Actuator Safety switch1 Control System Actuator Safety switch 2 Actuator Safety switch n Ex area I1 (FS) I2 (FS) Non-Ex area Evaluation Device FS: Fail-Safe Operating Manual PSEN cs5.13 M12/8 EX | 21 22218-EN-04...
Page 22
Evaluation device Fieldbus module FS: Failsafe ST: Standard Connection to Pilz evaluation devices Suitable Pilz evaluation devices are, for example: PNOZelog for safety gate monitoring PNOZpower for safety gate monitoring PNOZsigma for safety gate monitoring PNOZ X for safety gate monitoring Operating Manual PSEN cs5.13 M12/8 EX...
Page 23
The connections to two evaluation devices are shown on the following pages, by way of ex- ample: PNOZ s3 and PNOZmulti PNOZ s3 PNOZ s3 PSENcode Fieldbus module PNOZ s3 PSENcode Without SDD With SDD Operating Manual PSEN cs5.13 M12/8 EX | 23 22218-EN-04...
Input OSSD Input OSSD Signal input Teaching in the actuator Any approved Pilz actuator is detected as soon as it is brought into the response range. Installation DANGER! Risk of sparking due to electrostatic charging of the safety switch in...
Page 25
DEVICE INPUT SAFETY GATE INPUT If using angled connector plugs, note the defined angle of the cable routing. When installing make sure you comply with the requirements of EN ISO 14119. Operating Manual PSEN cs5.13 M12/8 EX | 25 22218-EN-04...
Page 26
Clause 7.2c of EN ISO 14119. Fig.: Seals [1]: 4 seals for actuators [2]: 2 seals for actuators [3]: 2 seals for actuators [4]: 2 seals for switches and 2 seals for actuators Operating Manual PSEN cs5.13 M12/8 EX | 26 22218-EN-04...
Operating distances may deviate if other arrangements are used. Note the maximum permitted lateral and vertical offset (see Operating distances [ Lateral and vertical offset [ 15]). Operating Manual PSEN cs5.13 M12/8 EX | 28 22218-EN-04...
32]. Display not Display not Supply voltage is at Ensure the voltage supply definitive definitive the limit of the toler- corresponds to the Tech- ance range yellow nical details [ 32]. Operating Manual PSEN cs5.13 M12/8 EX | 29 22218-EN-04...
Page 30
Display not Wrong actuator Use the actuator PSEN definitive cs5.13 M12 ATEX. green yellow Switch doesn't start Change the switch. yellow yellow Operating Manual PSEN cs5.13 M12/8 EX | 30 22218-EN-04...
2,4 W Potential isolation from system voltage Short circuit-proof Residual current at outputs 400 µA Voltage drop at OSSDs Conditional rated short circuit current 100 A Lowest operating current 2 mA Operating Manual PSEN cs5.13 M12/8 EX | 32 22218-EN-04...
Page 33
EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 Frequency 10 - 55 Hz Amplitude 1 mm Shock stress In accordance with the standard EN 60947-5-2 Acceleration Duration 11 ms Operating Manual PSEN cs5.13 M12/8 EX | 33 22218-EN-04...
Page 34
Yes, follow installation guidelines Connection type M12, 8-pin male connector Material PA+GF, PBT, polycarbonate Max. torque setting for fixing screws 1 Nm Dimensions Height 26,4 mm Width 101,6 mm Depth 19 mm Operating Manual PSEN cs5.13 M12/8 EX | 34 22218-EN-04...
A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PSEN cs5.13 M12/8 EX | 35 22218-EN-04...
2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Page 37
M12, 8‑pin, pin M12, 8- 540 338 M12 PIGTAIL pin, socket PDP67 F 4 code Decentralised passive junction 773 603 PDP67 F 4 code VA Decentralised passive junction, V2A ring nut 773 613 Operating Manual PSEN cs5.13 M12/8 EX | 37 22218-EN-04...
Page 38
European Parliament and of the Council. 2006/42/EC on machines 2014/34/EU (ATEX) 2014/53/EC on radio equipment The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/ downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN cs5.13 M12/8 EX...
Page 39
Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...
Need help?
Do you have a question about the PSEN cs5.13 M12/8 EX and is the answer not in the manual?
Questions and answers