York SUNLINE MAGNADRY WR 180 Technical Manual page 15

Gas/electric single package air conditioners
Hide thumbs Also See for SUNLINE MAGNADRY WR 180:
Table of Contents

Advertisement

262292-YTG-C-0707
TABLE 5: COOLING CAPACITIES FOR WR240 (CONTINUED)
Air on Evaporator Coil
Total
WB
CFM
Cap.
(°F)
(MBH)
77
72
5000
67
62
77
72
6000
67
62
57
77
72
7000
67
62
57
77
72
8000
67
62
57
72
67
8500
62
57
72
67
9000
62
57
1. The capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
All Sensible Capacity
Unitary Products Group
115°F
2
Sensible Capacity (MBH)
Total
1
Return Dry Bulb (°F)
Input
(kW)
90
85
240
21.3
101
86
221
21.0
140
120
202
20.7
179
155
185
20.4
184
184
253
21.4
126
97
233
21.1
158
135
214
20.8
190
173
195
20.5
194
194
194
19.7
194
194
267
21.6
151
108
246
21.3
176
150
225
21.0
202
192
206
20.7
205
205
205
19.8
205
205
280
21.8
176
119
258
21.5
195
165
236
21.1
213
211
216
20.8
215
215
215
20.0
215
215
252
21.4
198
168
231
21.1
209
201
211
20.8
210
210
210
19.9
210
210
247
21.3
202
172
226
21.0
205
190
206
20.7
205
205
205
19.8
205
205
Temperature of Air on Condenser Coil
*
Total
Cap.
(MBH)
80
75
70
65
66
46
27
-
101
81
61
42
135
115
96
76
159
139
120
100
74
51
28
-
112
89
66
43
150
127
104
81
177
154
131
108
177
154
131
108
81
55
29
-
124
97
71
44
166
139
113
87
196
169
143
116
196
169
143
117
89
59
29
-
135
105
76
46
181
152
122
92
214
184
154
124
214
184
154
125
138
108
78
48
185
155
125
95
209
179
149
119
210
180
149
119
141
111
80
50
190
159
129
98
205
175
144
114
205
175
144
114
125°F
2
Sensible Capacity (MBH)
Total
1
Return Dry Bulb (°F)
Input
(kW)
90
85
225
23.1
100
81
208
22.8
136
117
192
22.5
174
151
175
22.2
175
174
238
23.3
126
93
220
23.0
154
131
203
22.7
183
169
185
22.3
184
184
184
21.2
184
184
250
23.4
151
105
232
23.1
172
146
214
22.8
192
188
195
22.5
193
194
194
21.4
194
194
263
23.6
176
117
244
23.3
190
160
225
23.0
204
204
205
22.7
204
204
204
21.5
204
204
238
23.2
194
164
220
22.9
198
189
200
22.6
199
199
199
21.5
199
199
233
23.1
194
168
215
22.8
194
171
195
22.5
194
194
194
21.4
194
194
*
80
75
70
65
63
43
23
-
97
77
57
37
131
111
92
72
154
134
115
95
70
47
23
-
108
85
62
38
146
123
100
77
172
149
126
103
170
147
123
100
77
50
24
-
119
93
66
39
161
135
108
82
190
163
137
110
187
161
134
108
84
54
24
-
130
100
70
41
177
147
117
87
205
178
148
118
204
175
145
115
134
103
73
43
181
151
120
90
200
170
140
110
199
169
139
108
137
106
76
45
186
155
124
94
194
163
132
101
194
163
132
102
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunline magnadry wr 240Sunline magnadry wr 300

Table of Contents