Physical And Electrical Data - 3 Phase - York H*RD018 THRU 060 Technical Manual

Split-system air conditioners 13 seer – r-22
Hide thumbs Also See for H*RD018 THRU 060:
Table of Contents

Advertisement

254892-YTG-C-0606

PHYSICAL AND ELECTRICAL DATA - 3 PHASE

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
4
Compressor Type
Rated Load
Compressor Amps
Locked Rotor
Crankcase Heater
Fan Motor Amps
Rated Load
Fan Diameter Inches
Rated HP
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fin / Inches
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
5
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
1. Rated in accordance with ARI Standard 110, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. All scrolls listed with a superscript "B" are Bristol scrolls. All scrolls listed with a superscript "C" are Copeland scrolls.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
A
6
H1RD
H1RD
030S25
036S25
208-230V, 3φ, 60Hz
187 to 252
14.3
14.3
2
20
20
3
15
15
Recip
Recip
10.2
10.2
72
72
No
No
1.5
1.5
22
22
1/4
1/4
850
850
3100
3150
15.72
15.72
1
1
22
22
3/8
3/8
3/4
7/8
5 - 13
6 - 0
0.68
0.70
208
208
C
B
H1RD
H1RD
H1RD
042S25
048S25
060S25
12.4
21.5
23.1
20
35
40
15
25
25
Recip
ScrollB
ScrollB
8.8
16.0
17.3
72
115
123
No
No
No
1.5
1.5
1.5
22
22
24
1/4
1/4
1/4
850
850
850
3550
3550
3600
23.60
24.00
27.00
1
1
1
22
22
22
3/8
3/8
3/8
7/8
7/8
1-1/8
8 - 13
8 - 6
10 - 2
0.70
0.70
0.76
208
215
294
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
DIMENSIONS
Unit
Dimensions
Model
(Inches)
1
A
030
27
036
27
042
39
048
34
060
38
1. Including Fan Guard.
* Adapter fitting required for 1-1/8" line set.
H1RD
H1RD
H1RD
030S46
036S46
042S46
460V, 3φ, 60Hz
432 to 504
6.9
9.6
6.9
15
15
15
15
15
15
Recip
Recip
Recip
4.9
13.5
11.8
45
45
45
No
No
No
0.7
0.7
0.7
22
22
22
1/4
1/4
1/4
850
850
850
3100
3150
3550
15.72
15.72
23.60
1
1
1
22
22
22
3/8
3/8
3/8
3/4
7/8
7/8
5 - 13
6 - 0
8 - 13
0.68
0.70
0.70
208
208
215
Refrigerant Connection
Service Valve Size
B
C
Liquid
37
27
37
27
37
27
3/8"
43
32
43
32
Unitary Products Group
H1RD
H1RD
048S46
060S46
10.3
11.3
15
15
15
15
ScrollB
ScrollB
7.7
8.4
50
70
No
No
0.7
0.7
24
24
1/4
1/4
850
850
3550
3600
24.00
27.00
2
2
18
18
3/8
3/8
7/8
1-1/8
8 - 6
10 - 2
0.70
0.76
250
294
Vapor
3/4"
7/8"
7/8"*