Walchem WDSW100 Instruction Manual page 26

Disinfection sensors
Table of Contents

Advertisement

Ozone
Range
(W100, W600, W900)
0-20 mg/l
Sensitivity
Sample Flow rate
pH Range
Conductivity Range
Response time
Conditioning time
Hydrogen Peroxide
Range
(W100, W600, W900)
0-200 mg/l
0-2,000 mg/l
0-20,000 mg/l
Sensitivity
Sample Flow rate
pH Range
Conductivity Range
Response time
Conditioning time
Range (WDIS)
0-16.75 mg/l
ClO
(6%)
2
30 to 100 liters/hour (0.13 to 0.44 gal/min)
2.0 – 11.0
No Limit
50 sec
60 min
Range (WDIS)
0-167.5 mg/l
0-1,675 mg/l
0-16,750 mg/l
Chlorine (none may be present)
PAA (none may be present)
Ozone (none may be present)
30 to 100 liters/hour (0.13 to 0.44 gal/min)
2.0-11.0
No Limit
5-10 min
180 min
23
Range (WM1, WIND)
0-10 mg/l
Range (WM1, WIND)
0-100 mg/l
0-1000 mg/l
0-10,000 mg/l
Resolution
0.01 mg/l
Resolution
0.1 mg/l
1 mg/l
10 mg/l