Walchem WDSW100 Instruction Manual page 25

Disinfection sensors
Table of Contents

Advertisement

Total Chlorine
Range
(W100, W600, W900)
0-20 mg/l
Sensitivity
Sample Flow rate
pH Range
Conductivity Range
Response time
Conditioning time
Chlorine Dioxide
Range
(W100, W600, W900)
0-2 mg/l
0-20 mg/l
0-200 mg/l
Sensitivity
Sample Flow rate
pH Range
Conductivity Range
Response time
Conditioning time
Peracetic Acid
Range
(W100, W600, W900)
0-200 mg/l
0-2,000 mg/l
0-20,000 mg/l
Sensitivity
Sample Flow rate
pH Range
Conductivity Range
Response time
Conditioning time
Range (WDIS)
0-16.75 mg/l
ClO
(100%)
2
Ozone (130%)
30 to 100 liters/hour (0.13 to 0.44 gal/min)
4.0 – 12.0
No Limit
2 min
120 min
Range (WDIS)
0-1.67 mg/l
0-16.75 mg/l
0-167.5 mg/l
Free Chlorine (5%)
Ozone (2500%)
30 to 100 liters/hour (0.13 to 0.44 gal/min)
1.0 – 11.0
No Limit
30 sec
60 min
Range (WDIS)
0-167.5 mg/l
0-1,675 mg/l
0-16,750 mg/l
Ozone (250%)
ClO
(100%)
2
H
O
(0.5%)
2
2
30 to 100 liters/hour (0.13 to 0.44 gal/min)
1.0 – 7.0
No Limit
3 min
60 min
22
Range (WM1, WIND)
0-10 mg/l
Range (WM1, WIND)
0-1.0 mg/l
0-10 mg/l
0-100 mg/l
Range (WM1, WIND)
0-100 mg/l
0-1000 mg/l
0-10,000 mg/l
Resolution
0.01 mg/l
Resolution
0.001 mg/l
0.01 mg/l
0.1 mg/l
Resolution
0.1 mg/l
1 mg/l
10 mg/l

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wcnp100Wds600W900Webmaster

Table of Contents