Maintenance; Test Leads; Aaa Batteries - UNI-T UT 61+ Series User Manual

1000v true rms digital multimeter
Table of Contents

Advertisement

12) Indicator Light
Function
Status
Off
<36V
NCV
50V~1000V (the red indicator light flashes from slow to fast)
On, red
Off
OL
Continuity
On, red
No continuity (≥70Ω)
On, green
Continuity (<50Ω)
Off
>2V
On, red
Breakdown (<0.12V)
Diode
On, green
Conduction (0.12V~2V)
≤1000V
Off
AC/DC
voltage
On, red
>1000V
≤10A
Off
Current
On, red
>10A
Internal
The temperature in the meter drops to <40°C
Off
after measurement of large current.
temperature
during AC/DC
The temperature in the meter is ≥75°C
current
On, yellow
after measurement of large current.
measurement
X. Maintenance
Warning: Before opening the rear cover or battery cover of the meter,
switch off the power supply and remove the test leads.
1. General Maintenance
1) Clean the meter casing with a damp cloth and mild detergent. Do not use
abrasives or solvents!
2) If there is any malfunction, stop using the meter and send it for maintenance.
3) The maintenance and service must be implemented by qualified professionals
or designated departments.
35
Description
4) Resistance measurement can be used to check the built-in 1A and 10A fuses.
Operation (Picture 18a): Insert the red test lead into the
Insert the red probe into the mA/μA input terminal to measure the resistance.
If the LCD displays "OL", the 1A fuse is blown. Insert the red probe into the A
input terminal to measure the resistance. If the LCD displays "OL", the 10A
fuse is blown.
2. Battery/Fuse Replacement (Picture 18b)
Battery: 4×1.5V AAA batteries
Fuse: F1 Fuse 1A 240V Φ6x25mm (mA/μA input terminal)
F2 Fuse 10A 240V Φ6x25mm (A input terminal)
When "
" is displayed, please replace the batteries in time to ensure
measurement accuracy.
Replacement steps:
1) Turn the function dial to the "OFF" position, and remove the test leads.
2) Unscrew and remove the battery cover to replace the batteries and fuses.
FUSED
250V max
MAX 10sec
EACH 15min
х
RANGE
≤1Ω
≤1Ω
10A
OL
mAµA
≤20MΩ
OL
Picture 18a
The contents of this manual are subject to change without prior notice.
or
terminal.
Picture 18b
36

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ut61e+Ut61b+Ut61d+

Table of Contents