Setting Groove Diameter - Anvil GRUVLOK 1007 Manual

Roll gro0ver
Hide thumbs Also See for GRUVLOK 1007:
Table of Contents

Advertisement

1007 & 3007 ROLL GROOVER
SETTING GROOVE DIAMETER - STEEL PIPE & CTS COPPER SYSTEM
For proper set-up and positioning of pipe, refer to instructions as shown on page 9
Increase the pump pressure to the recommended set-up
1
pressure shown in the chart for the size and wall thickness
pipe to be grooved.
2
Slide the "C" shaped groove diameter gauge, for the pipe size to be
grooved under the adjustable Knurled Stop at top left side of the groover
base. Each gauge is marked with two (2) size ranges. Place the correct
pipe size area, for the size being grooved, under the adjustable knurled
nut. When grooving pipe with a diameter of 14"-16", use the area
marked 12".
The groove body diameter gauges are mounted on the back of the
groover body.
Note: For CTS Copper System, use the CTS Depth Gauge
3
Turn the Knurled Stop to snug against the surface of the groove diameter
gauge. Release the pump pressure by turning the pump release valve
counterclockwise and remove the groove diameter gauge.
10
STEEL PIPE
RECOMMENDED SET-UP PRESSURE (BOTH MODELS)
Pipe Size
Wall
Inches
Schedule
2" - 6"
10
8"-12"
10
14"-16"
10
2"
40
2
/
"-4"
40
1
2
5"- 6"
40
8"- 10"
40
12"
STD.
14"-16"
STD.
CTS COPPER SYSTEM
RECOMMENDED SET-UP PRESSURE (BOTH MODELS)
Tube Size
Wall
Inches
Type
2"-4"
K, L, M, DWV
5"-6"
K, L, M, DWV
8"
K, L, M, DWV
"RIDGID" is a registered trade mark of Emerson Electric Company.
*
Set-up Pressure
PSIG
100
2,000
2,000
100
2,500
3,600
4,000
4,600
4,600
Set-up Pressure
PSIG
100
200
400

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gruvlok 3007