Mounting on a Recessed Drop-Ceiling T-Bar
Note:
This mounting bracket can also be used on a flush
drop-ceiling T-bar, so the four rubber feet on the bottom of the
AP minimize ceiling tile displacement.
The enclosed T-bar bracket supports mounting to recessed drop ceiling
T-bars.
Mounting an AP using the External Bracket
Removing an External Bracket from a T-Bar
Removing an External Bracket from an AP
Mounting an AP using the External Bracket
Figure 10.
1
Insert the unit removal pin (A in
Figure 10.
side of the Unleashed R500 (B in
locking mechanism.
Figure 10. . Attaching the external bracket to the AP
A
B
2
Position the studs on the bottom of the T-bar bracket (C in
Figure 10.
) in the mounting holes on the Unleashed R500
enclosure, and then slide the T-bar bracket until the studs are in
the narrow parts of the Unleashed R500 mounting keyholes
(arrow).
Figure 10.
Remove the unit removal pin (A in
3
locking mechanism and secure the T-bar bracket to the
Unleashed R500.
Figure 10.
Make sure that the locking tab (D in
4
Figure 10.
position on the T-bar bracket (C in
5
Gently push the ceiling tiles up and out of the way.
6
Position the T-bar bracket so its two clasps grip one edge of
Figure 11.
the T-bar (A in
). Make sure that both clasps are
gripping the T-bar.
Figure 11. . Attaching the external bracket to the T-bar
A
B
Copyright © 2015 Ruckus Wireless, Inc.
Published September 2015, Part Number 800-70564-002 Rev C
Hold the Unleashed R500 in place and gently push the locking
7
tab (B in
Figure 11.
bar.
CAUTION:
T-bar!
Removing an External Bracket from a T-Bar
Move the ceiling tiles out of the way.
1
Gently lift up the locking tab (A in
2
fingers under the tab.
3
While lifting up on the locking tab, rotate the Unleashed R500-
and-T-bar bracket assembly (B in
) into the hole on the
R500-and-T-bar bracket assembly comes away from the T-bar.
) to release the
Figure 12. . Removing the external bracket from the T-bar
C
D
Removing an External Bracket from an AP
1
Insert the unit removal pin (A in
side of the Unleashed R500.
2
Gently lift up the retainer tab (B in
3
Gently push the T-bar bracket (C in
from the Unleashed R500.
Figure 13. . Removing the external bracket from an AP
) to engage the
) is in the first
).
) until its clasp grips the other edge of the T-
Make sure that all three clasps are gripping the
Figure 12.
) by sliding your
Figure 12.
). The Unleashed
A
B
Figure 13.
) into the hole on the
Figure 13.
).
Figure 13.
) until it detaches
A
C
B
Mounting on a Flush Drop-Ceiling T-Bar
Mounting an AP using the Integrated Bracket
Removing an AP Integrated Bracket from a T-Bar
Mounting an AP using the Integrated Bracket
1
Orient the AP so that the T-bar is positioned between the T-bar
Figure 14.
clips as shown in
, then rotate the AP until the third
T-bar clip catches the T-bar and the latch locks the T-bar in
Figure 15.
place (
).
Figure 14. . Attaching the integrated bracket to the T-bar
Figure 15. . Locking the integrated bracket to the T-bar
2
Insert the Torx security screw into the hole near the latch to lock
the AP in place.
Removing an AP Integrated Bracket from a T-Bar
1
To remove the AP from a T-bar, first remove the security screw,
then depress the latch while rotating the AP so that the T-bar
clips disengage the T-bar.
Mounting on a Truss or Pole
1
Feed the customer-supplied cable ties through the two slots on
the back of the Unleashed R500.
Fasten the Unleashed R500 to the truss or pole using the cable
2
ties.