Mounting Configurations - Recom RCM 6MB Series Installation And Safety Instructions

60/72 cell monocrystalline/polycrystalline/ silicon modules
Hide thumbs Also See for RCM 6MB Series:
Table of Contents

Advertisement

5. MOUNTING CONFIGURATIONS

Select the proper installation method depending on the mounting method.
Figure 1: Mounting Configurations
MODULE ILLUSTRATION
CASE 1
FRONT VIEW
BACK VIEW
CASE 2
FRONT VIEW
BACK VIEW
Installation Instructions UL-1703 and IEC / Rev. 05-2018 V.5
RECOM © Copyright 2018
LOGO PARAMETERS
Bolt Mount
Maximum
Locations:
Rear Load:
Fixed bolt
2400 Pa
location for
(50 psf)
5400 Pa
front load
Clamp Mount
Locations:
A
Fixed clamp
location for
2400 Pa front
load
Maximum
Bolt Mount
Locations
Rear Load:
2400 Pa
(50 psf)
Clamp Mount
Locations:
C
Clamp mount
allowable
range
UL AND IEC INSTALLATION GUIDE
Maximum
Structural rails running perpen-
dicular to the length of the mod-
Front Load:
ule should be fixed via bolts at the
mounting holes between each
5400 Pa
long side frame, or Clamps can be
(113 psf)
mounted at the Fixed Clamp Mount
location as shown in the color code
key.
Maximum
Structural rails running parallel to
the length of the module should be
Front Load:
fixed via bolts at the mounting holes
on each long side frame, or Clamps
5400 Pa
can be mounted anywhere within
(113 psf)
the Clamp Mount Range as shown
in the color code key.
DETAILS