Recom RCM-6MB Series Installation And Safety Instructions

60/72 cell monocrystalline silicon
Hide thumbs Also See for RCM-6MB Series:

Advertisement

Installation and Safety Instructions
IEC version
THIS DOCUMENT APPLIES TO THE FOLLOWING
RECOM PHOTOVOLTAIC MODULES:
60 Cell Monocrystalline Silicon Modules:
RCM-xxx-6MB (xxx=270-310)
60 Cell Polycrystalline Silicon Modules:
RCM-xxx-6PB (xxx=260-280)
72 Cell Monocrystalline Silicon Modules:
RCM-xxx-6MA (xxx=315-360)
72 Cell Polycrystalline Silicon Modules:
RCM-xxx-6PA (xxx=310-340)
Installation Instructions IEC / Rev. 05-2018 V.5
RECOM © Copyright 2018
IEC INSTALLATION GUIDE
p. 1 of 14
www.recom-solar.com

Advertisement

Table of Contents
loading

Summary of Contents for Recom RCM-6MB Series

  • Page 1 60 Cell Monocrystalline Silicon Modules: RCM-xxx-6MB (xxx=270-310) 60 Cell Polycrystalline Silicon Modules: RCM-xxx-6PB (xxx=260-280) 72 Cell Monocrystalline Silicon Modules: RCM-xxx-6MA (xxx=315-360) 72 Cell Polycrystalline Silicon Modules: RCM-xxx-6PA (xxx=310-340) Installation Instructions IEC / Rev. 05-2018 V.5 p. 1 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 2: Table Of Contents

    Installation method Attachment guidelines 4. ELECTRICAL INSTALLATION General installation guidelines Grounding 5. MAINTENANCE 6. DISCLAIMER OF LIABILITY 7. DECOMMISSIONING AND RECYCLING 8. PRODUCT INFORMATION Installation Instructions IEC / Rev. 05-2018 V.5 p. 2 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 3: Introduction

    IEC INSTALLATION GUIDE 1.INTRODUCTION Thank you for selecting RECOM Photovoltaic Modules. The RECOM Photovoltaic Modules are designed and manufactured to the highest quality standards. With correct installation and maintenance, RECOM modules will keep providing clean energy for many years. How to use this manual •...
  • Page 4: Handling Safety

    When storing uninstalled panels outdoors for any period of time, always cover the panels and ensure that the glass faces upwards to stop water from collecting inside the panel and causing damage to exposed connectors. Installation Instructions IEC / Rev. 05-2018 V.5 p. 4 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 5: Installation Safety

    The modules have been rated Fire Class C, and are suitable for mounting onto a fire retardant roof covering rated for the application at a minimum distance of 10 cm from the panel to the roof plane. Installation Instructions IEC / Rev. 05-2018 V.5 p. 5 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 6: Product Identification

    Always observe the instructions and safety precautions included with the module support frames. • Do not attempt to drill holes in the glass surface of the modules as this will void the warranty. Installation Instructions IEC / Rev. 05-2018 V.5 p. 6 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 7: Installation Method

    Dust building up on the surface of the module can impair module performance. • RECOM recommends installing the modules with a tilt angle of at least 10 degrees, making it easier for dust to be washed off by rain. •...
  • Page 8: Attachment Guidelines

    5,400 Pa are also valid for 3,800 Pa and 2,400 Pa. The installation methods applicable for 3,800 Pa are also valid for 2,400 Pa. Installation Instructions IEC / Rev. 05-2018 V.5 p. 8 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 9 Use insertion system on short side Use insertion system on short side and 2 clamps at the center on long sides of each long side Installation Instructions IEC / Rev. 05-2018 V.5 p. 9 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 10: Electrical Installation

    Secure cables using UV-resistant cable ties or other UV-resistant devices. Loose cables must be protected from abrasion, sharp objects, animals etc. Avoid exposing cables as far as possible to direct sunlight and permanent tension. Installation Instructions IEC / Rev. 05-2018 V.5 p. 10 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 11: Grounding

    • RECOM modules can be installed with the use of third party grounding devices for grounding the frames of PV modules. The devices have to be installed in accordance with the grounding device manufacturer’s specified instructions.
  • Page 12: Disclaimer Of Liability

    • The information in this manual is based on RECOM’s best knowledge and experience and is believed to be reliable; but such information including product specification (without limitations) and suggestions do not constitute a warranty, express or implied. RECOM reserves the right to change the manual, the PV product, the specifications, or product information sheets without prior notice.
  • Page 13: Product Information

    IEC INSTALLATION GUIDE 8.PRODUCT INFORMATION Structural Drawings RCM-XXX-6MB & RCM-XXX-6PB Module dimensions in mm Installation Instructions IEC / Rev. 05-2018 V.5 p. 13 of 14 RECOM © Copyright 2018 www.recom-solar.com...
  • Page 14 IEC INSTALLATION GUIDE RCM-XXX-6MA & RCM-XXX-6PA Module dimensions in mm Installation Instructions IEC / Rev. 05-2018 V.5 p. 14 of 14 RECOM © Copyright 2018 www.recom-solar.com...