Specifications
and Safety
OVERALL DIMENSIONS:
SHIPPING WEIGHT: 42.5 LBS.
JUNIOR CLAMP HEAD
1.
FAMILIARIZE YOURSELF WITH OPERATING
PROCEDURES BEFORE OPERATING THE S10099 AIR
TOOL.
2.
DO NOT OPERATE TOOL WITHOUT SLIDE COVER IN
PLACE.
3.
USE ONLY RECOMMENDED BAND-IT PREFORMED
CLAMPS OR BAND AND BUCKLE WITH THE PROPER
HEAD ASSEMBLY.
4.
DO NOT EXCEED RECOMMENDED PRESSURE SETTINGS.
EXCESS PRESSURE MAY CAUSE SUDDEN CLAMP
FAILURE DURING APPLICATION OR RESULT IN AN
UNSAFE CLAMP. CERTAIN APPLICATIONS MAY REQUIRE
A REDUCED PRESSURE SETTING. SEE PAGE 6 FOR
RECOMMENDED PRESSURE SETTINGS. ALSO SEE PAGE
6 FOR IMPORTANT ADVICE AND WARNINGS.
AIR LINE PRESSURE:
CONSUMPTION:
LINE SIZE:
CONNECTION:
FILTER / LUBRICATOR:
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
20 ¼" LONG
9 7/8" WIDE
13 ¼" HIGH
CONTROL LEVER
PULL SPEED CONTROL
SLIDE COVER
CUT OFF HANDLE

SAFETY PROCEDURES

AIR LINE REQUIREMENTS

100 PSI MINIMUM, 150 PSI MAXIMUM (7.0 – 10.5 kg/cm
3-5 CFM WITH 20 GALLON TANK MIN.
1/4" ID MINIMUM
1/4" NPT
MUST BE ADDED TO AIR SUPPLY. SEE PAGE 18 FOR BAND-IT FILTER /
LUBRICATION KIT
www.BAND-IT-IDEX.com
PRESSURE SETTING CONTROL
5.
ALWAYS KEEP FINGERS CLEAR OF CLAMP DURING
APPLICATION.
6.
DISCONNECT AIR SUPPLY BEFORE SERVICING AIR
TOOL.
7.
TOOL MUST BE FIRMLY MOUNTED (SEE INSTALLATION
INSTRUCTIONS ON PAGE 4).
8.
SAFETY CLASSES OR GOGGLES SHOULD BE WORN
WHEN APPLYING CLAMPS.
9.
ALWAYS KEEP TOOL IN GOOD OPERATING CONDITION.
Page 3 of 18
S10099
Classic Air Tool
AIR SUPPLY INLET
PRESSURE SETTING
CHART