Removal of Indoor Heat Exchanger
Step
2. Remove the indoor unit.
Detach the indoor unit
1
from the installation
plate.
3. Remove the piping fixture.
Unfasten the hook on
1
the upper side of the
piping fixture on the
back of the unit.
4. Remove the indoor heat
exchanger.
Slightly widen the
1
auxiliary piping.
Unfasten the hooks on
2
the left side.
16
Procedure
Piping fixture
Auxiliary piping
Points
(R2797)
(R2798)
(R2799)
Caution
When removing or
reinstalling the indoor heat
exchanger, be sure to wear
protective gloves or wrap the
indoor heat exchanger with
cloths. (You may be injured
Hooks
by the fins.)
(R5482)