Download Print this page
Manrose COMT Series Installation Instructions

Manrose COMT Series Installation Instructions

Wall fans

Advertisement

Quick Links

INSTALLATION
Installation Instructions for the
COMT and COMTK Range of Wall Fans
Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory and mental capabilities
or lack of experience and knowledge if they have been given
supervision or instruction concerning the use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Precautions must be taken to avoid the back-flow of gases into the
room from the open flue of gas or other open-fire appliances when
mounted in outside windows or walls.
Fan must be disconnected from electrical power before any
maintenance is carried out.
Location
1. When installing fan through an external wall, an
external wall grille must be fitted at all times.
2. For best results this Extractor Fan should be
fitted as high on the wall as possible, or if
preferred, on the ceiling. Note: Pullcord models
should not be installed in a ceiling.
3. Do not install the unit within a shower cubicle
or anywhere else where there is a risk of being
sprayed with water (Please see our range of
showerfans for these installations.).
4. If the fan is installed in a room containing a fuel
burning appliance, the installer must ensure that
the air replacement is adequate for both the fan
and the fuel burning appliance.
INSTRUCTIONS
Wiring
1. Switch off mains supply before making electrical
connections. If in any doubt contact a qualified
electrician.
2. These units are for fixed wiring only. A flexible cord
must not be used. All wiring must be fixed securely
and the cable to the fan should be a minimum of
1mm
in section. All wiring must comply with current
2
I.E.E. Regulations or local regulations if outside the
UK.
3. A double pole fused spur having contact separation
of at least 3mm in all pole must be used and fitted
with a 3A fuse.
4. This fan is double insulated and does not require an
earth connection.
5. The fan should not be accessible to a person using
either the shower or the bath.

Advertisement

loading

Summary of Contents for Manrose COMT Series

  • Page 1 INSTALLATION INSTRUCTIONS Installation Instructions for the COMT and COMTK Range of Wall Fans Switch off mains supply before making any electrical connections. Installation must be supervised by a qualified electrician. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory and mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a...
  • Page 2 3. Build in the sleeve and make good around the edges. The external and internal grilles have a flange that over hangs the sleeve. COMT Series 4. Is supplied without the sleeve and external grille. The series is designed as a replacement for existing installations and fits most makes of sleeve and wall box with little or no modifications to the existing wall box installations.
  • Page 3 138mm COMT300 470mm 470mm 154mm 6. Electrical Connections (COMTK/COMT Series) COMTK150 & COMT150 This model can only be wired for extract. Connect the power into the terminal located on the rear of the fan. Connector Cable Grip 1 LIVE SUPPLY...
  • Page 4 Plug Wiring Diagram NEUTRAL IN LIVE IN Diagram A EXTRACT ONLY NEUTRAL IN LIVE IN Diagram B INPUT ONLY EXTRACT ONLY IN INPUT ONLY IN NEUTRAL IN LIVE IN Diagram C REVERSIBLE SPEED CONTROLLER WIRING DIAGRAM DIAGRAM A - EXTRACT ONLY To change the airflow direction remove link from terminal 1 in the plug and connect into terminal 2.

This manual is also suitable for: