Technical Data System 7001 - hopf Elektronik GmbH 7001GPS Technical Manual

Satellite clock system with control board 7020gps
Table of Contents

Advertisement

T
D
S
ECHNICAL
ATA
YSTEM
6

Technical Data System 7001

General Data
Housing:
Housing dimensions:
Housing protection class:
Protection class:
Cooling:
Display:
Keypad:
Operation:
MTBF (Basis Board 7020):
Weight (Basis System):
Environmental Conditions
Temperature:
Humidity:
Operating Voltage
Standard:
Option:
Power Consumption:
CE compliant in accordance with EMC Directive 89/336/EEC and Low Voltage Direc-
tive 73/23/EEC
Safety /
Low Voltage Directive:
EMC (Electromagnetic Com-
patibility) / Interference Resis-
tance:
Interference voltage:
Backup Clock
Accuracy:
Buffering (maintenance-free):
42 / 44
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
7001
Aluminium, closed
19" System, 3U/84HP (132,5mm / 482,6mm), depth
230mm
IP20
I
passive cooling
system a minimum of 1 U to the next device.
VFD-Display: 2x40-digit (colour: green)
Character height: 5mm; Display type: alphanumeric
Optional:
Status / Error LEDs
42 keys
Via keypad and VFD-Display
> 290.000 hours
Approx. 5kg (depends on system configuration level)
Operating:
0°C to +55°C
Storage:
-20°C to +75°C
Max. 95%, not condensed
120/230V AC +10% -15% / 30VA
48V DC (36V - 72V) / 30VA
24V DC (18V - 36V) / 30VA
Other power supplies on request
Depends on power supply and configuration level of
system (see type plate)
DIN EN 60950-1:2001
+ A11 + Corrigendum
EN 610000-4-2 /-3 /-4 /-5 /-6 /-11
EN 61000-3-2 /-3, EN 61000-6-2 /-4
EN 55022 Class B
± 25ppm at +10°C to +50°C
3 days
attend convection: above and below
7001GPS Satellite Clock System - V08.00

Advertisement

Table of Contents
loading

Table of Contents