System Byte - hopf Elektronik GmbH 7001GPS Technical Manual

Satellite clock system with control board 7020gps
Table of Contents

Advertisement

K
EYPAD

4.3.6 System Byte

Validity: all systems
Various system functions can be switched on and off with the system byte.
Selection screen
SET SYSTEM BYTE Y/N
Input screen
OLD BYTE >00000001<
NEW BYTE >_ <
The significance of the individual bits is as follows:
B7
3D/Position-fix
0
Position-fix evaluation.
1
3D evaluation.
B6
Synchronisation process
0
Standard synchronisation process.
Special synchronisation process / system time status becomes invalid ("–") when the
1
time difference between the internal clock and the synchronisation source is more than
one second.
B5
Error message / switch box control
0
Common error message output on occurrence of a major or minor alarm event.
1
Output control for switch box (5000 system).
B4
Error message / PPS pulse output
0
PPS pulse on the 9-pole SUB-D connector X1, pin 4.
Common error message (major or minor alarm event) on the 9-pole SUB-D connector X1,
1
pin 4.
Time base in the Master/Slave-String (e.g. when synchronising with sync.
B3
module 8023)
0
The time base in the Master/Slave-String is local time (standard setting).
1
The time base in the Master/Slave-String is UTC.
B2
Evaluation of the Master/Slave-String
0
Standard evaluation with all string information.
1
Special evaluation for application with sync. module 8023.
Bit 1 Bit 0 Setting the signalling bit for Summertime-/ Wintertime switchover
0
0
Signalling bits are only set by the external source.
0
1
Signalling bits are set via the external source depending on the system status of the ex-
ternal source or via the internal switchover times:
1
0
Signalling bits are only set in accordance with the internal switchover times of the 7001
system (e.g. required for synchronisation with sync. module 8023).
1
1
Signalling bits are only set via the internal switchover times of the 7001 system (e.g.
required for synchronisation with sync. module 8023).
7001GPS Satellite Clock System - V08.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
Signalling bits are set by the external source provided that this delivers valid
time information.
Signalling bits are set by the internal switchover times of the 7001 system when
the external source is not available.
21 / 44