General Information For Input - hopf Elektronik GmbH 7001GPS Technical Manual

Satellite clock system with control board 7020gps
Table of Contents

Advertisement

K
EYPAD
Keypad entries / system control
The main menu is activated by pressing the "ENT" key.
The display changes over from the standard frame, display of time information, or from
4
blanking
to the main menu.
Start frame:
SET:1 SHOW: 2 BOARDS:3 MON: 4
PROG-RESET: R MASTER-RESET:M
The individual modes have the following meaning:
SET:
SHOW:
BOARDS:
MON:
PROG.-R:
MASTER-R:

4.2.1 General Information for Input

When the appropriate figure or letter is entered the menu item requested appears or is exe-
cuted (reset). The individual menu items are designed with user commands.
With key "BR" it is possible to leave the input menu at any time and at any position.
The sub-functions of the menu group are shown on the display and are
accepted with "Y" = Yes
or rejected with "N" = No.
When "N" is entered the next sub-function is displayed. When "Y" is entered the appropriate
sub-function appears.
Some sub-functions display the old value input at the same time.
The cursor in the frame shows at which position the next input can be made.
Each input can be corrected with "BS" (Back Space).
Each new complete input must be finished with "ENT". If no new input is made but "ENT" is
pressed directly then the old value will be used.
If the input of only one piece of information is required then the display will return to the sub-
function inquiry when "ENT" is pressed.
If several inputs are required then, after "ENT" is pressed the cursor switches to the next in-
put position and only returns to the sub-function inquiry after the last input has been made.
4
for display protection the display can be set to switch automatically to blank (see Chapter 4.3.5
Control Byte)
14 / 44
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
Enter or view set functions such as time/date, position, time offset etc.
View information e.g. satellite values
Enter control functions for system extension boards
Monitor function, this function is only used in-plant.
By entering "R" in PROG.-R the programme is re-started on Board 7020.
By entering "M" a hardware master reset of the whole system is started. All
boards in the system are resetted and
re-started.
7001GPS Satellite Clock System - V08.00