EYPAD
In the first line of the display the data of the synchronous line which was last queried are
shown: Synchronous line No. S.-CLK No.:01, synchronous line status ST=R(un), current
pulse length I=1.0 s and the time T:11.50.41.
Input of synchronous line number: if the data of the other synchronous lines are to
be queried or changed the synchronous line number must be entered in the second
line. The input of the number is in two digits in the range from 01..15. If the input of
the number is outside the permissible range an error message will appear.
After input of the synchronous line number the first line in the display is updated ac-
cordingly, if the synchronous line entered is available within the system.
Input of synchronous line status: here the input of S(top) can stop synchronous line
pulse output or the input of R(un) can start synchronous line pulse output.
Input of synchronous line pulse length: here the pulse length can be set in the range
of 0.2 .. 3.0 seconds. If the input of the pulse length is outside the permissible range
the minimal 0.2 or maximal 3.0 seconds pulse length is pre-set.
Input of synchronous line time: here the synchronous line time is re-set. The syn-
chronous line time is entered according to the hh.mm.ss format/sample, whereby
the following inputs are possible:
hh
mm
ss

4.4.2 BOARD 7270 / 7271 / 7272 (LAN)

Selection frame:
BOARD 7270 / 7271 / 7272 (LAN) Y/N
With this function the most important network time server parameters of the LAN board can
be queried and/or re-set. Further information can be found in the technical board description.
Querying or setting takes place in two stages (two different input frames).
1. Input frame:
No:_:
NEW
>_
The LAN board no. is required here as the first input (1
The input of the LAN board number is as a single digit in the range 1..8. If a number
outside the permissible range is entered an error message appears.
7001GPS Satellite Clock System - V08.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
hour
range from 00 - 23
minute
–– " –– from 00 - 59
second
–– " –– from 00 – 59
Before the Synchronous line time is set, stopping the synchronous line is
recommended.
:
.
>
.
Only one board number is assigned for each LAN board (independent of the
board type).
.
.
.
.
<
st
input frame).