2. RIVER 600 supports the use of third party solar panels (DIY solution)
Users can buy universal solar panels of MC4 connection standard on their own to power RIVER 600, as long
as the voltage and current (10-25V DC, 12A Max) comply with the specifications of RIVER 600, the panels will
be able to recharge RIVER 600 through the MC4 to XT60 conversion cable. However, EcoFlow do not provide
free repair services for any damage to the product caused by the quality issue or improper operation of the
third-party solar panels, even in the warranty period.
SOLAR CABLE

Entry-Level UPS

RIVER 600 Entry-level UPS Use Reminder
Entry-level UPS function. RIVER 600's X-STREAM system supports an entry-level UPS function. You can use the
RIVER 600 AC socket while the device is connected to a wall socket with AC power supply (the AC power comes
from the grid, not the battery). When the grid loses power suddenly, the device can automatically switch to RIVER
600 RRO battery power mode in <30ms to ensure your work is uninterrupted. This is an entry-level grade UPS
function that does not support 0ms switching. Do not connect devices with high uninterrupted power supply
requirements. Perform multiple tests to confirm compatibility before connecting such devices as data servers
and workstations with RIVER 600. EcoFlow will not be responsible for any loss of data or equipment damage
caused by users' failure in following the instructions. For example, data server and workstation, otherwise it will
affect your user experience. The parallel mode uses Parallel Cables to connect the Parallel Outlets of two prod-
ucts to provide almost doubled power of a single product. Since the UL2743 standard socket cannot be grounded
effectively, please connect the grounded wire to the grounding screw port of the input end according to your own
needs, to ensure the safety using of the electrical appliances.
Entry-Level UPS User Guide
Users can connect the AC charging cable of RIVER 600 to the power grid and connect a device to RIVER
600 and turn on the AC switch to automatically enter the entry-level UPS mode. When the external power is
cut off, power will be supplied from the battery of RIVER 600 immediately to protect your device (as shown
below).
* UPS is only applicable to electrical appliances below 600W. Please do not use other equipment at the same
time to avoid OVERLOAD. EcoFlow is not responsible for any abnormal operation or data loss caused by
careless use. Only one RIVER 600 can conduct the UPS function. To connect, follow the instructions below.
More than one RIVER 600 connected CANNOT conduct the UPS function.
11