D.4.4) Adjusting for Width Coverage... (continued)
Table 2— Overall Dimension of Coverage Area Zones
Mounting
Height
84"
118"

D.4.5) Setting Width coverage

Adjust the pattern width to achieve proper detection area width per ANSI
Right bank
of switches
9 - 16
Important Note to the Installer
CAUTION:
The Acuvision emits active reflective infrared rays that detect the changing light intensity
reflected from the floor surface in the detection area. The detection area is the reference area
as determined by the Acuvision. Detection sensitivities can vary depending on the color of the
object being detected. Care should be taken to ensure sensor is adjusted to reliably detect
colored objects consistently.
Detection areas will fluctuate as the sensitivity is adjusted.
Be sure to confirm that the detection area is properly adjusted after any sensitivity
adjustments are made.
Page 14
Coverage Areas
1-7 Active
84"
118"
9 10 11 12 13 14 15 16
1
2 3 4 5 6 7
1
2
3
ON ON
2 3
OFF
ON
3
OFF OFF
ON OFF
Figure 5 - Adjustment of width of detection
*Area 4 cannot be deleted.
*After adjusting the depth, turn ON the power again.
*All the setting switches are ON by factory default.
For example, when you want to have areas 4, 5,
6 and 7 active, dip switches #13, #14, #15 and
#16 are going to be ON, OFF, ON, ON.
www.NabcoEntrances.com
Coverage Width change
per Zone Switch
12"
15"
ON
OFF
5
6
4
7
ON
ON
5 6
ON OFF
4
5
4
OFF
OFF
4
OFF ON
Acuvision Instruction Manual