Wiring; General Wiring Information - Nabco Gyro Tech Acuvision Instruction Manual

Table of Contents

Advertisement

Wiring

D.2
D.2.1) General Wiring Information
Color of wire
Brown
Red
Black (N.O.)
OUTPUT #1 --- Activation Signal Output
Green (COM)
Gray (INPUT)
INPUT #1 --- Fully Closed Signal Input
If there is a possibility of swing /folding doors open-
ing slightly from the fully closed position due to wind
or stack pressure, this input signal may be required
in order for the sensor to recognize when the door is
Yellow (INPUT)
in the fully closed position. A mechanical or magnet-
ic door closed switch is necessary for this function.
This signal can be output automatically from
Microprocessor U series. (No signal required on
Sliding doors.)
White (N.O.)
OUTPUT #2 --- Safety Signal Output
<Swing/folding side of the Swing/Folding Doors>
Safety Signal Output: Connected to Locked out
Blue (COM)
safety input of Control box.
<Sliding Door>
Not used
Note !
Because sensor "looks"
backward through the threshold
area, it must not be obstructed
by the mounting surface.
Therefore, when using sensor
on swing, fold, or sliding doors,
install no higher than 1.5"
above bottom of header as
shown at right.
Page 7
Function
12VDC
GND
www.NabcoEntrances.com
Acuvision Instruction Manual
24VAC
Use "Class 2" Power Supply
30VAC/50VDC 0.1A Max.
A dry switch contact is required.
30VAC/50VDC 0.1A Max.
Notes
(Resistance load)
[Semiconductor Relay]
For swing doors use:
1 x P/N 14-11313
For folding doors use:
1 x P/N 14-11343-20
1 x P/N 14-11313-20
(Resistance load)
[Semiconductor Relay]
Sensor should be installed
no higher than 1.5" from
the bottom edge of header
DN0183
05-11-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

14-10823-01

Table of Contents