D.7) Troubleshooting

D.7.1) Sensor symptoms and how to solve them

Symptoms
Possible Causes
Power・Connector Defects
No
Function
Abnormal Power Voltage
Sensor Lens is stained with
dirt, water, etc.
No
Low Sensitivity
Detection
Wrong Detection Area Set-
ting
High Sensitivity
Detection Area Overlapped
by other Detecter(s)
Not Detecting Door
Movable Object(s) placed in
Detection Area
Conditions in Detection Ar-
Mis-detection
ea altered
Operation Display Red LED
Blinks Several Times at Ful-
ly Opened Position
Operation Display Amber
LED Blinks Several Times
at Fully Open Position
Operation Display Green LED Blinks
Operation Display Red LED Blinks
Standstill Memory Time (Learn Time) is
Short

D.7.2) Sensor symptoms using wrong Door Mode settings

Mode
Folding Door Setting
Type
Folding Door
○ Normal Operation
No activating signal at fully
Sliding Door
closed position, thus no
opening door.
Swing Door
△ Operational
Page 20
Measures
Check Wiring Cable and Connector
Rated Voltage for This Sensor is 12~24V AC/DC.
apply voltages other than the rated voltages. Use Class 2 power
supply.
Wipe off the stain with neutral detergent applied soft cloth. (Do
not use such chemicals as Thinner or Alcohol, etc.)
Set higher sensitivity
Make readjustments with Area Setting Switches, Area Setting
Lever, Area Fine Adjustment Mechanism
Lower Sensitivity at the Setting Switch.
Set the different Interference Prevention Modes by setting
switches.
Check to ensure Detection Area is tilted toward Door panel.
Readjust the Detecting Area to avoid objects or remove the ob-
ject(s) to outside the Detection Area.
When conditions in Detection Area change, the Sensor keeps
on detecting as long as the time set for Presence Detection.
Shorten the Presence Detection Time at the setting switch.
Detection is made by Door Detector. Lower the sensitivity.
(Example: SW4=OFF, SW5=ON )
Detection is made by Door Detector. Lower the sensitivity.
( Example: SW4=OFF, SW5=ON )
The sensor does not recognize the movement of Door. Readjust
the area toward Door side by Area Fine Adjustment Mechanism.
Self-Diagnosis Function Determines the unit Out of Order.
After turning power on, allow up to 3 minutes without anyone
entering the detection pattern for the sensor to stabilize.
Sliding Door Setting
Repeated reverse motions or
opens at fully closed posi-
tion.
○ Normal Operation
Repeated reverse motions or
opens at fully closed posi-
tion.
www.NabcoEntrances.com
Acuvision Instruction Manual
Do not
Swing Door Setting
△ Operational
No activating signal at fully
closed position, thus no
opening door.
○ Normal Operation