D.2.4) Wiring - Non-swing side of swing door with Magnum Control
Insert new Acuvision cable (PN # 22-11023) into drilled hole in header. Connect Acuvision
harness to Magnum terminal block as shown below. Mount the Acuvision Sensor.
Note: Acuvision dipswitch Settings: (9 ON & 10 OFF)
HOLE ON
THE
HEADER
COVER
ACUVISION HARNESS
HOLE
ON THE
HEADER
COVER
ACUVISION HARNESS
Page 9
BROWN
RED
GREY
YELLOW
WHITE
BLUE
GREEN
BLACK
BROWN
12/24 VOLTS AC/DC
RED
12/24 VOLTS AC/DC
GREY
INPUT
YELLOW
INPUT COM
WHITE
OUTPUT#2 N.O.
BLUE
OUTPUT#2 COM
GREEN
OUTPUT#1 COM
BLACK
OUTPUT#1 N.O.
www.NabcoEntrances.com
12/24 VOLTS AC/DC
12/24 VOLTS AC/DC
INPUT
INPUT COM
OUTPUT#2 N.O.
OUTPUT#2 COM
OUTPUT#1 COM
OUTPUT#1 N.O.
NOT USED
Acuvision Instruction Manual
MAGNUM BOARD
TERMINAL BLOCK
CONNECTIONS
TERMINAL # 1
TERMINAL # 2
NOT USED
NOT USED
NOT USED
NOT USED
TERMINAL # 5
TERMINAL # 6
24 VAC
TRANSFORMER
P/N 14-2101
24 VAC
DOOR CLOSED INPUT
SEE NOTE ON PG. 18
TO EXTERNAL
LOCKOUT MODULE
TO RED (COMMON)
RED WIRE ABOVE IS FOUND
ON FOUR WIRE MAT HARNESS
ON ANALOG CONTROL
BROWN
ORANGE
RED
BLACK
DN0183
DN0183
05-11-10