Usb Interfaces; Fig. 7-5: Usb Interfaces Xusb1 And Xusb2 - Bosch Rexroth IndraControl VDP 16.1 Series Project Planning Manual

Hide thumbs Also See for Rexroth IndraControl VDP 16.1 Series:
Table of Contents

Advertisement

VDP 16.1, VDP 40.1 and VDP 60.1

USB Interfaces

XUSB – Serial Interfaces for
Printer, Scanner, CD-ROM Drive
DOK-SUPPL*-VDP16/40/60-PR02-EN-P
The devices feature two USB interfaces on the connector panel (XUSB1
and XUSB2) and one in the front panel (not for devices for the food
industry).
Note:
The maximum power consumption of the connected device
must not exceed 500 mA. If the load exceeds 500 mA, the
internal current monitoring is activated.
Note:
The USB interfaces are not supported by the operating system
Windows NT4.0.
XUSB
XUSB
1
2
3
4
Shield
Fig. 7-5:
USB interfaces XUSB1 and XUSB2
Pin
Function
1
USB power supply (max. 500 mA)
2
Data -
3
Data +
4
USB ground
Note:
It is only possible to connect USB Devices fulfilling the USB
specification. However, USB devices that e. g., don't maintain
the reaction time, are also commercially available.
Thus, the general function of such non-specification-compliant
USB devices can not be guaranteed, even if they are working
e. g. at the USB interface directly at the IPC.
1
USB device
USB_P
2
USB1
3
USB2
4
USB_M
Shield applied to the metal housing
of the plug-in connection
7-3