Vdp 16.1 And Vdp 40.1; Fig. 6-8: Key Combinations Of The Keys Vdp 16.1Bk And Vdp 40.1Bi; Fig. 6-9: Key Combinations Of The Keys Vdp 16.1Bk And Vdp 40.1Bi - Bosch Rexroth IndraControl VDP 16.1 Series Project Planning Manual

Hide thumbs Also See for Rexroth IndraControl VDP 16.1 Series:
Table of Contents

Advertisement

VDP 16.1, VDP 40.1 and VDP 60.1

VDP 16.1 and VDP 40.1

Addressing of the M-Keys
DOK-SUPPL*-VDP16/40/60-PR02-EN-P
Function and Operation Keys (F... + OP...)
The assignment of the function and operation keys is determined by the
respective application software / the used operating system.
Use of an External Keyboard
Concerning the VDP 16.2BK and VDP 40.2BI keypad the key functions
can also be activated with an external PC keyboard by pressing the
following key combinations:
Keys of the VDP 16.1BK and
VDP 40.1BI
OP2
to
OP9
PROG
Fig. 6-8:
Key combinations of the keys VDP 16.1BK and VDP 40.1BI
M-Keys
Eight M-Keys (machine function keys) are allocated at the right and the
left side of the display (see Fig. 6-6). The keys on the right side of the
display are labeled with R1 to R8, the keys on the left side of the display
with L1 to L8.
The status of the M-Keys can be retrieved by several ways:
• Pressed M-Keys are transmitted as PS/2 signals to the PC.
• They can be transferred to a soft control installed on the PC via the
serial interface COM3.
• At last, the signals are output at the optional plug XDP as outputs of a
PROFIBUS DP slave.
Display and Operating Components
Corresponding key of a standard
keyboard
CTRL + SHIFT + ALT + F2
CTRL + SHIFT + ALT + F9
CTRL + SHIFT + ALT + Q
CTRL + SHIFT + ALT + I
6-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents