1 Button
2 Front part of the casing
3 Suction hose for detergent
4 Weight
5 Foot valve
6 Hook
7 Hose for detergent solution
8 Fastening hole
9 Outlet of detergent solution
10 Nozzle insert
11 Input of detergent
12 Floading ring
13 Water inlet
14 Locking

Device installation

 Install the accompanying pipe air-re-
lease valve on the water inlet.
Observe the flow direction (arrow) and
the vertical fitting position.
8

Operating and Functional Elements

 Press on the lock and remove the cabi-
net front.
 Position the appliance in a way that the
foot valve is located at least 1 m below
the pipe air-release valve.
 Mark 3 fastening holes on the wall
through the back of the casing.
 Drill 3 holes with a diameter of 8 mm ap-
prox. 40 mm deep into the wall.
 Insert the included dowels all the way
into the holes.
 Screw the included screws into the top
two dowels.
 Hook the cabinet back onto the screws.
 Turn in the bottom screw and tighten all
the screws.
 Select the nozzle insert for the desired
mixing ratio:
– 2