All electrical connections must be performed by
a certified electrician following all national and
External Circuit Breaker and Shut Off Required
208-240 volt single phase units must be hardwired to your electrical
system utilizing an external circuit breaker and shut off mounted as
close as possible to the oven.
380-400 volt 3 phase units are provided with a 16A-6h plug and 8' of
VDE rated cord. The oven must be connected to an external circuit
breaker and shut off mounted as close as possible to the oven.
Oven
Model
5A 6B
7C
8D-2
8E
Oven
Model
5A 6B
7C
8D-2
8E

Electrical Connections

local codes and regulations.
208-240 Volt Single Phase
Actual
Amperage
20 Amp
23 Amp
59 Amp
39 Amp
380-400 Volt Three Phase
Actual Amperage
Per Phase
8 Amp
9 Amp
23 Amp
16 Amp
Recommended
Circuit Breaker
Recommended
Circuit Breaker
Regulations
7
30 Amp
30 Amp
70 Amp
50 Amp
Check
Local and
National