Torques; Positioning Of Mixers And Flowmakers - Grundfos SMD Series Installation And Operating Instructions Manual

Mixers and flowmakers, 60 hz, north america
Table of Contents

Advertisement

5.1 Torques

All nuts and bolts used for the installation must be made of
stainless steel.
Use grease, alu-paste, together with a spring washer or locking
nut. Otherwise, use Loctite or a similar product for lubrication and
locking.
Tighten all nuts and bolts to the following torques:
Size
1/4" (M6)
5/16" (M8)
7/16" (M10)
1/2" (M12)
5/8" (M16)
3/4" (M20)
5.1.1 Anchor bolts
Anchor bolts used for mounting components in concrete must
have the following pull-out strength:
Size
1/2" (M12)
5/8" (M16)

5.2 Positioning of mixers and flowmakers

Correct positioning of mixers and flowmakers is essential to
ensure trouble-free operation and long life.
5.2.1 Mixers
Submerge the mixer as deeply as possible.
Place the mixer in such a way that you obtain a good mixing of
the liquid in the entire tank. If more mixers are installed in the
same tank, the mixers must not generate opposite flows.
The distance between the propeller tip and the bottom of the
tank, H
in fig. 3, must be half of the propeller diameter.
MIN
SMG: The distance from the propeller tip to the liquid surface,
H
in fig. 3, must be at least equal to the propeller
ABOVE
diameter.
SMD: The distance from the propeller tip to the liquid surface,
H
in fig.
3
must be at least 1.5 times the propeller
ABOVE
diameter.
The distance between the propeller tip and the wall behind the
mixer, L
in fig. 3, must be at least 1.5 times the propeller
MIN
diameter.
Bolts
ASTM F593 (V/W)
[lbf (Nm)]
6.5 (8.8)
15.8 (21.4)
32.5 (44)
54.6 (74)
135 (183)
273 (370)
Pull-out strength
[kipf (kN)]
1.35 (6)
3.15 (14)
L
MIN
Fig. 3
Positioning sketch for mixers
5.2.2 Flowmakers
Submerge the flowmaker as deeply as possible.
The distance between the propeller tip and the bottom of the
tank, H
in fig. 4, must be 20 in (50 cm).
MIN
The distance from the propeller tip to the liquid surface,
H
in fig. 4, must be at least 0.75 times the propeller
ABOVE
diameter.
The distance between the propeller tip and the wall behind the
flowmaker, L
in fig. 4, must be at least twice the propeller
MIN
diameter.
The sideways distance between the propeller tip and the tank
wall must be at least 1.6 ft (0.5 m).
If more flowmakers are to be installed in parallel, the distance
between their propellers must be larger than half the propeller
diameter.
The distance from a bend in the channel to the propeller and
from the propeller to aeration areas must be at least the larger
value of channel width and water level.
Fig. 4
Positioning sketch for flowmakers
L
MIN
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smg seriesSfg series

Table of Contents