KROHNE OPTISWIRL 4070 Supplementary Instructions Manual

KROHNE OPTISWIRL 4070 Supplementary Instructions Manual

Vortex flowmeter
Hide thumbs Also See for OPTISWIRL 4070:

Advertisement

OPTISWIRL 4070
OPTISWIRL 4070
OPTISWIRL 4070
OPTISWIRL 4070
Vortex flowmeter
Equipment category II3G
© KROHNE 05/2016 - 4001268803 - AD OPTISWIRL 4070C Ex-II3G R04 en
Supplementary Instructions
Supplementary Instructions
Supplementary Instructions
Supplementary Instructions

Advertisement

Table of Contents
loading

Summary of Contents for KROHNE OPTISWIRL 4070

  • Page 1 OPTISWIRL 4070 OPTISWIRL 4070 OPTISWIRL 4070 OPTISWIRL 4070 Supplementary Instructions Supplementary Instructions Supplementary Instructions Supplementary Instructions Vortex flowmeter Equipment category II3G © KROHNE 05/2016 - 4001268803 - AD OPTISWIRL 4070C Ex-II3G R04 en...
  • Page 2: Table Of Contents

    CONTENTS OPTISWIRL 4070 1 Safety instructions 1.1 General notes ........................3 1.2 EU conformity ........................3 1.3 Safety instructions......................3 2 Device description 2.1 Device description ......................4 2.2 Description code....................... 4 2.3 Marking..........................5 2.4 Flammable products ......................7 2.5 Equipment category ......................
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS OPTISWIRL 4070 1.1 General notes These additional Ex instructions apply to explosion-protected versions of the vortex flowmeters with the marking II 3 G. They complement the standard documentation for non-explosion protected versions. The information given in these Instructions contains only the data relevant to Category 3 explosion protection.
  • Page 4: Device Description

    * positions which are not needed are omitted (no blank positions) The remote version consisting of the OPTISWIRL 4000 flow sensor and the VFC 070 F signal converter is called the OPTISWIRL 4070 F. www.krohne.com 05/2016 - 4001268803 - AD OPTISWIRL 4070C Ex-II3G R04...
  • Page 5: Marking

    DEVICE DESCRIPTION OPTISWIRL 4070 2.3 Marking The marking key is used to mark the devices using the nameplates as illustrated here. On both the compact devices and the remote versions, the main plate is located on the converter housing. On the remote versions there is an additional marking on the flow sensor.
  • Page 6 DEVICE DESCRIPTION OPTISWIRL 4070 Remote version 1 Product designation 2 Materials of flow sensor and sealing 3 Serial number 4 Year of manufacture 5 Ex data 6 PED data 7 Circuits 8 Observe operating instructions 9 Manufacturer's website www.krohne.com 05/2016 - 4001268803 - AD OPTISWIRL 4070C Ex-II3G R04...
  • Page 7: Flammable Products

    DEVICE DESCRIPTION OPTISWIRL 4070 2.4 Flammable products Atmospheric conditions An explosive atmosphere is a mixture of air and flammable gases, vapours, mists or dusts under atmospheric conditions. It is defined by the following values T = -20...+60°C / -4...+140°F and P = 0.8...1.1 bar /...
  • Page 8: Protection Types

    DEVICE DESCRIPTION OPTISWIRL 4070 2.6 Protection types 2.6.1 Protection types for the compact version The vortex flowmeter is designed in the "non-sparking" protection type in accordance with EN 60079-15. Explosion protection is ensured in that there are no contacts or hot surfaces with a sparking effect during operation.
  • Page 9: Ambient Temperature / Temperature Classes

    DEVICE DESCRIPTION OPTISWIRL 4070 2.7 Ambient temperature / temperature classes The permissible range of ambient temperatures for vortex flowmeters is noted on the nameplate and is T = -40°C...+60°C / -40°F...+140°F Because of the influence of the temperature of the product, no fixed temperature class is assigned to vortex flowmeters.
  • Page 10 DEVICE DESCRIPTION OPTISWIRL 4070 Permissible product and ambient temperatures with signal converter or sensor connection box Permissible product and ambient temperatures with signal converter or sensor connection box Permissible product and ambient temperatures with signal converter or sensor connection box...
  • Page 11 DEVICE DESCRIPTION OPTISWIRL 4070 Permissible product and ambient temperatures with signal converter / sensor connection box installed laterally or below the measuring unit Maximum permissible product and ambient temperatures per temperature class in °C Temperature class T2…T1 in °C Size DN15…25...
  • Page 12: Electrical Data

    DEVICE DESCRIPTION OPTISWIRL 4070 2.8 Electrical data Signal circuits Signal circuits Signal circuits Signal circuits The vortex flowmeter signal circuits may only be connected to circuits with the following nominal values: A+/A • U = 14...36 V • I = 4...20 mA B+/B •...
  • Page 13: Installation

    INSTALLATION OPTISWIRL 4070 3.1 Special conditions Equipotential bonding Vortex flowmeter converters must be included in the equipotential bonding of the hazardous area. 3.2 Installation Installation and setup must be carried out according to the applicable installation standards (e.g. EN 60079-14) by qualified personnel trained in explosion protection. The information given in the manuals and the supplementary instructions must be observed at all times.
  • Page 14: Electrical Connections

    ELECTRICAL CONNECTIONS OPTISWIRL 4070 4.1 General notes The separate signal circuits are electrically connected in the terminal compartment of the signal converter. The separate sensor circuits are connected in the terminal compartments on the wall bracket and flow sensors. The connecting cables for signal circuits must be selected and connected according to prevailing installation standards (e.g.
  • Page 15: Grounding And Equipotential Bonding

    ELECTRICAL CONNECTIONS OPTISWIRL 4070 4.4 Grounding and equipotential bonding CAUTION! Equipotential bonding Equipotential bonding Equipotential bonding Equipotential bonding Vortex signal converters must be included in on-site equipotential bonding acc. to EN 60079-14! They are connected to the PA terminals. In the case of compact meters and measuring units with flange connections, the sensor is conductively connected to the pipeline.
  • Page 16: Sensor Circuits (Remote Version Only)

    ELECTRICAL CONNECTIONS OPTISWIRL 4070 4.5 Sensor circuits (remote version only) Observe the following points when connecting the flow sensor to the signal converter: • Use only the supplied connecting cable (max. length 15 m / 49 ft). • Before connecting or loosening the equipotential bonding cable, ensure there are no differences in potential.
  • Page 17: Operation

    OPERATION OPTISWIRL 4070 5.1 Start-up Start-up may only commence when the vortex flowmeter: • is correctly installed in the system and connected. • has been checked for the proper state with regard to its installation and connection requirements. The user of the system must have it checked before start-up in compliance with the national regulations for checks before startup.
  • Page 18: Service

    SERVICE OPTISWIRL 4070 6.1 Maintenance Maintenance work of a safety-relevant nature within the meaning of explosion protection may only be carried out by the manufacturer, his authorised representative or under the supervision of authorised inspectors. For systems in hazardous areas, regular tests are required in order to maintain the proper condition.