Operation
Technical Data
Display
Range
Overload
Measuring rate
Operating temperature
Operating environment
Dimension
Weight
Current supply
Current consumption
Electric Specifications
Measuring Range
0 – 1999 Lux
2000 – 19990 Lux
20000 – 100000 Lux
Accuracy was determined with a wolfram lamp with 2854°K tempera-
ture.
30
18mm high Liquid Crystal Display
0 – 100000 Lux in 3 steps
pointing with „1" in display
0,4 seconds
0° to 50°C (32° to 122°F)
lower than 80% R.H.
130 x 72 x 30mm
170g incl. battery
9V Block 6F22
lower than 2mA
Solution
1 Lux
10 Lux
100 Lux
Accuracy
(23±5°C)
± 4%
± 4%
± 5%
®
Testboy