Technical Data - MANN+HUMMEL ProVent Series Installation And Maintenance Manual

Oil separator for open and closed crankcase ventilation systems
Table of Contents

Advertisement

MANN + HUMMEL ProVent

6 Technical Data

Also see the corresponding order drawing (on request).
Reference value for the
use of ProVent
Blow-by volume flow
Installation position
Permitted angled position
of high axis
Positioning
Ambient temperature
Mounting, screwing
connection on engine
block
Material
Resistant to
Weight
Possible use of parallel
connection of two
ProVent of same size
MANN+HUMMEL Industrial Filters
ProVent
100
up to 100 kW
max.100 l/min max.150 l/min
Inlet
2 positions
Outlet
4 positions
Housing
Lid
Holder
0.25 kg
X
ProVent
ProVent
150
200
up to 200 kW
up to 250 kW
max. 200
l/min
vertical
45° in all directions
1 position
additional on
request
12 positions
can be
rotated in 3°
steps
-35°C to 120°C, briefly up to 140°C
2xM8
PA GF
Diesel fuel, engine oil, lubricating oil, cold cleaner
0.33 kg
0.39 kg
X
ProVent
400
up to 500 kW
max. 400
l/min
12 positions
1.20 kg
X
X
ProVent
800
up to 1,250
kW
max. 800
l/min
stepless
2xM10
Steel sheet
PA GF
Steel sheet
5.41 kg
X
22