Excess Flow Safety Valve Reset Procedure; Care And Maintenance - Broil King 06695000 Operator's Manual

Propane gas barbecue
Table of Contents

Advertisement

Available languages

Available languages

WARNING:
Always monitor the grill closely when cooking and turn the flame level down to LOW or OFF if flare-ups intensify.
Shutting Off Burners
1.
Always turn the valve knob(s) clockwise to the ''HIGH'' position, and then press and turn it to ''OFF''. Never force the knob
without pressing it. This could damage the valve.
2.
Promptly turn the gas supply to the "OFF" position at the propane cylinder.
3.
Close the lid of the grill.

Excess Flow Safety Valve Reset Procedure

The new regulators are equipped with a safety device that restricts the gas flow in the event of a gas leek. However,
unsafe practices of grill operation could activate the safety device without having a gas leak.
A sudden shut off of the gas flow typically occurs if you open the LP tank valve rapidly, or if one or more of the burner
control knobs is in an open position when opening the LP tank valve.
To ensure the procedure is safely and successfully performed, please carefully follow these instructions:
1.
Close the LP tank valve.
2.
Turn all burner control knobs to the OFF position.
3.
Disconnect the regulator from the LP tank.
4.
Open the lid of the grill.
5.
Turn burner control knobs to HIGH.
6.
Wait at least 1 minute.
7.
Turn burner control knobs OFF.
8.
Wait for at least 5 minutes.
9.
Re-connect the regulator to the LP tank.
10.
Slowly turn the LP tank valve ¼ turn at a time and have the valve all the way open.
11.
With the lid open: For grill with ignition button: turn on only ONE burner control knob to the HIGH position. Ignite
the grill by pushing the ignition button.
12.
After the first front burner is lit, turn on the other control knob(s) to the HIGH position. If you have more than two
burners, turn them on only ONE AT A TIME.
13.
When all front burners are lit, close the grill lid.
14.
Wait for 10-15 minutes; the temperature should reach 400 – 450°F.
WARNING:
The cylinder valve always has to be above the horizontal position, for the cylinder to have vapour withdrawl only.
CORRECT
IMPORTANT
Always allow to completely cool off before covering your grill to prevent corrosion from condensation.
CAUTION:
All cleaning and maintenance should be done when the grill is cool, with the fuel supply turned off at the control dial and the
propane cylinder disconnected. DO NOT clean any grill part in a self-cleaning oven. The extreme heat will damage the finish.
Cleaning
Burning off the grill after every use (approx. 15 minutes) will keep excessive food residue from building up. Clean the grill
before and after cooking is recommended.
Recommended cleaning materials:
Mild dishwashing liquid detergent
Nylon cleaning pad
Paper clip
Compressed air
DO NOT use cleaners that contain acid, mineral spirits or xylene.
Outside surfaces
Use a mild dishwashing detergent and hot water solution to clean. Rinse thoroughly with water.
Inside surface
GPC2700JD
Instruction Manual
Guide d'utilisation
WRONG

Care and Maintenance

Hot water
Wire brush
Putty knife/scraper