Excess Flow Safety Valve Reset Procedure - Broil King EG300 Owner's Manual

Lp gas barbecue grill
Table of Contents

Advertisement

4. Clean the grill after each use. DO NOT use abrasive or flammable cleaners. This may damage parts of the grill and cause
a fire.
Confirm that the burner is properly lit and that the flame pattern is as desired (see fig. A, B and C below for the proper
flame patterns). If the flame pattern is other than normal, consult the Troubleshooting on page 18 for corrective action.
FIG. A
Normal: Soft blue flames with yellow
tips between I inch - 2 inches high.
Burner installation and adjustment
End edge should face towards upside.
Flare-ups
"Flare-ups" sometimes occur when food drippings fall onto the hot heat distribution plate or burners and ignite. Some flaring is
normal and desirable as it helps impart the unique flavors associated with grilled foods. Controlling the intensity of the flare-ups is
necessary, however, in order to avoid burned or unevenly cooked foods and to prevent the possibility of accidental fire.
WARNING:
Always monitor the grill closely when cooking and turn the flame level down to LOW or OFF if flare-ups intensify.
Shutting Off Burners
1.
Always turn the valve knob(s) clockwise to the ''HIGH'' position, and then press and turn it to ''OFF''. Never force the knob
without pressing it. This could damage the valve.
2.
Promptly turn the gas supply to the "OFF" position at the propane cylinder.
3.
Close the lid of the grill.

Excess Flow Safety Valve Reset Procedure

The new regulators are equipped with a safety device that restricts the gas flow in the event of a gas leek. However,
unsafe practices of grill operation could activate the safety device without having a gas leak.
A sudden shut off of the gas flow typically occurs if you open the LP tank valve rapidly, or if one or more of the burner
control knobs is in an open position when opening the LP tank valve.
This procedure effective with all LP Tank sizes as well as Natural Gas. When performing the procedure on a Natural Gas
model, simply substitute "Natural Gas valve" for "LP Tank
To ensure the procedure is safely and successfully performed, please carefully follow these instructions:
1.
Close the LP tank valve.
2.
Turn all burner control knobs to the OFF position.
3.
Disconnect the regulator from the LP tank.
4.
Open the lid of the grill.
5.
Turn burner control knobs to HIGH.
6.
Wait at least 1 minute.
7.
Turn burner control knobs OFF.
EG300 Broilchef LP Gas Grill
Owner's Manual
2 in.
1 in.
Observe flame height when lit: Flame should be a blue/yellow
color between 1 to 2 inches.
0 in.
Out of adjustment: Noisy hard blue
flames – too much air.
1.
Release the screw on venturi tube.
2.
Adjust the flame by turning the collar on head
of venturi tube from back side of the grill and do
not take apart the venturi tube.
3.
Tighten the screw and make certain it is
secured
FIG. B
.
17
FIG. C
Poor combustion: Wavy, yellow
flames- too little air.
1.
Overlap 14 mm between
venturi tube and nozzle
when assembling.
2.
Keep the center line of venturi
tube and nozzle on one line.

Advertisement

Table of Contents
loading

Table of Contents