Verifying the configuration
Once the configuration is done, it can be verified from the status page.
established to Access Controller the AC Online Time is shown.
If the AC Online Time is not shown within few minutes:
-
Double check the configuration and Internet connection
-
Reboot the gateway (power off/on)
Connection to Access controller can be verified also with Debug Tools in Other tab:
-
abb.cassia.pro, Time 5s and press Start. To check connection to Access Control-
ler, select Ping, add Address abb.cassia.pro (or gw.smartsensor.abb.com.cn in
case of China).
-
To verify UDP ports open/close status select netcat, add Address abb.cassia.pro
(or gw.smartsensor.abb.com.cn in case of China), Protocol UPD, Timeout 2,
Port 5246-5247 and press Start.
NOTE! Remember to change the router mode to AC Managed Router mode. If the mode is
!
not changed, the gateway is not establishing a connection to AC server and the data is
not read form the Smart Sensors.