FMS winderGLIDE BKS.D.6 Series Installation Manual

FMS winderGLIDE BKS.D.6 Series Installation Manual

Actuator for unwind and rewind stations

Advertisement

Quick Links

Installation Manual
FMS winderGLIDE Type BKS.D.6
Actuator for unwind and rewind stations
Document Version
1.20 08/2017 NS
Diese Bedienungsanleitung ist auch in Deutsch erhältlich.
Bitte kontaktieren Sie Ihren nächstgelegenen FMS Vertreter.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the winderGLIDE BKS.D.6 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMS winderGLIDE BKS.D.6 Series

  • Page 1 FMS winderGLIDE Type BKS.D.6 Actuator for unwind and rewind stations Document Version 1.20 08/2017 NS Diese Bedienungsanleitung ist auch in Deutsch erhältlich. Bitte kontaktieren Sie Ihren nächstgelegenen FMS Vertreter. © by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved...
  • Page 2: Table Of Contents

    Installation Manual FMS winderGLIDE BKS.D.6 Table of Contents Safety Instructions ..................3 1.1 Description Conditions 1.2 List of Safety Instructions Product Data ....................4 2.1 Mechanical Dimensions 2.2 Order Code (Example) winderGLIDE Type D.6 2.3 Scope of Delivery Installation ....................6 3.1 Assembly Conditions...
  • Page 3: Safety Instructions

    Installation Manual FMS winderGLIDE BKS.D.6 1 Safety Instructions 1.1 Description Conditions a) High danger of health injury or loss of life Danger This symbol refers to high risk for persons to get health injury or loss of life. It has to be followed strictly.
  • Page 4: Product Data

    Installation Manual FMS winderGLIDE BKS.D.6 2 Product Data 2.1 Mechanical Dimensions Fig. 1: Outline Drawing Actuator BKS.D.6.0001 Fig. 2: Outline Drawing Power Supply Unit BKS.D.6.0003 07.08.2017...
  • Page 5: Order Code (Example) Winderglide Type

    Installation Manual FMS winderGLIDE BKS.D.6 Dimensions (see Fig. 1 and Fig. 2) in mm [in] Steering offset L 125 [4.9] or 200 [7.9] Bracket distance A in center position of toggle link 236 [9.3] + L sockets Total length B at full travel positions 236 [9.3] + 2L...
  • Page 6: Installation

    Installation Manual FMS winderGLIDE BKS.D.6 3 Installation 3.1 Assembly Conditions The winderGLIDE BKS.D.6 is defined as “partly completed machinery” according to the Directives 2006/42/EC, article 2. In order to assure a proper functionality of the parts and guarantee the essential health and safety requirements of operators...
  • Page 7 Installation Manual FMS winderGLIDE BKS.D.6 Fig. 3: Mounting Devices of BKS.D.6 BKS.D.6.0002e The static part of the winderGLIDE must be mounted to the machine frame e.g by means of the spherical rod end on the gearbox or the flange at the end of the spindle housing.
  • Page 8: Bks.d.6 System Overview

    Installation Manual FMS winderGLIDE BKS.D.6 3.3 BKS.D.6 System Overview Fig. 4: winderGLIDE BKS.D.6 components and cabling BKS.D.6.0009e 3.4 Installation on unwinding station Tension_Control_Web_Guiding_Scheme_Schema.ai 07.08.2017...
  • Page 9: Installation On Winding Station

    Installation Manual FMS winderGLIDE BKS.D.6 3.5 Installation on winding station Tension_Control_Web_Guiding_Scheme_Schema.ai 3.6 Connecting the Actuator widerGLIDE BKS.D.6 Fig. 5: Cable Terminals of the Power Supply Unit DRA240 BKS.D.6.0007e 07.08.2017...
  • Page 10 Installation Manual FMS winderGLIDE BKS.D.6 Danger The main supply terminal on the Power Supply Unit can be under a tension of 95- 264 VAC. Mortal danger! Only specially instructed and qualified personnel should handle the cabling of this unit. In any case the main supply may only be switch on after having properly connected the cables on the terminal.
  • Page 11: Pin Assignment On Actuator Connectors

    Fig. 6: Wiring diagram winderGLIDE BKS.D.6 BKS.D.6.0008e 4 Functional Description The FMS-winderGLIDE D.6 is an actuator designed for guiding unwind and rewind stands. It utilizes a powerful and high accuracy stepper motor with 2500N of thrust force to ensure the most accurate positioning of even the heaviest stands. When compared to hydraulic systems, this actuator operates clean and is suitable for the food and pharmaceutical packaging industry.
  • Page 12 Installation Manual FMS winderGLIDE BKS.D.6 FMS Force Measuring Systems AG FMS Italy FMS USA, Inc. FMS UK Aspstrasse 6 Via Baranzate 67 2155 Stonington Ave. Suite 119 Highfield, Atch Lench Road 8154 Oberglatt (Switzerland) I-20026 Novate Milanese Hoffman Estates, IL 60169 USA Church Lench Tel.

This manual is also suitable for:

Winderglide bks.d.6.0001Winderglide bks.d.6.0003

Table of Contents