Appendix K. Measuring Part Strengthening For Lls Fuel Level Sensors - Omnicomm LLS 20230 Installation Manual

Fuel tankers
Table of Contents

Advertisement

Connection
Appendix K. Measuring Part Strengthening for LLS Fuel Level
Sensors
IMPORTANT! Strengthening the measuring part of the LLS fuel level sensors is only
allowed for removable filler caps.
Option 1. Strengthening the measuring part of LLS fuel level sensors using steel pins
and collars.
Materials used:
3 x М6 Ø16 female steel collars
3 x М6 Ø20 female steel collars
DIN 975 М16 threaded pin – 3×2...3 m (depending on the size of the installed LLS
fuel level sensor)
DIN 975 М6 threaded pin (1 m)
6 x DIN 934 М16 nuts
6 x DIN 125 Ø17 flat washers
6 x DIN 127 Ø16.2 grovers (spring washers)
Automobile sealant
It is forbidden to use plumbing collars with rubber seals that are not intended for use
in aggressive environments.
Installation procedure: 1. Remove the filler cap. 2. Do 3.2, 3.4, 3.5, 3.6 with due regard to
the recommended LLS fuel level sensor installation place on the filler cap (Figure 44).