Installing Bis 20240 (For Lls 20230) - Omnicomm LLS 20230 Installation Manual

Fuel tankers
Table of Contents

Advertisement

Installing BIS 20240 (for LLS 20230)

IMPORTANT! Strengthening the measuring part of the LLS fuel level sensors is only
allowed for removable filler caps. Refer to the Appendices K, L for the detailed
description of methods for strengthening the measuring part of the LLS fuel level
sensors.
Installing BIS 20240 (for LLS 20230)
1) Fix BIS 20240 on selected surface by self-tapping screws or bolts according to
installation dimensions (Figure 35, Appendix F). 2) Make an electric connection of BIS
20240 to the vehicle body or to the Ground bus terminal (with earthed element of
stationary fuel storage structure) with a copper wire with the cross-section of at least
4 mm2.
The electrical resistance of the conductor between the body of BIS 20240 and the
body of the vehicle or Ground bus terminal should not exceed 0.1 Ohm.