Installation and Deinstallation

"Settings" tab, "Configurable Parameters" section:
"Network address" (1 to 254) – set the sensor network address. If several sensors are
connected to one external device, each of them should have unique network
addresses.
"Max. level (1...4095)" — select the maximum sensor reading. Default value – 4,095.
"Min. level (0...1023)" — select the minimum sensor reading. Default value – 0.
"Filtration" – set the output signal filtration parameters:
"No" – no filtration. Used for filtration by an external device.
"Minimum" filtration is used when the device is installed in stationary fuel storages
and non-mobile machinery
"Average" filtration is used when the vehicle operates under normal road
conditions
"Maximum" filtration is used when the vehicle operates under harsh road
conditions
"Automatic data output" – select:
"No output" – no data output without request
"Binary" – autonomous binary data output
"Character" – autonomous character data output
"Data output interval" (1 to 255 seconds) – set the autonomous data output interval
"Heavy exploitation conditions" mode – switch on to enable additional measurement
filtration that considers harsh conditions
"Baud rate" – select data exchange rate when communicating with an external device.
Default value – 19200 bit/s.
Installation and Deinstallation
To make the works go smooth, it is recommended to perform product setting prior to
installation works (see Paragraph 5).

Product Installation

13