Midi Data Format - Yamaha PLG150-VL Owner's Manual

Yamaha virtual acoustic plug-in board owner's manual
Hide thumbs Also See for PLG150-VL:
Table of Contents

Advertisement

MIDI Data Format

1. KEY ON / KEY OFF
Status: 9nH/8nH
If the Part Parameter Rcv NOTE MESSAGE = OFF, that Part will ignore Key ON and Key
OFF messages.
2. PROGRAM CHANGE
Status: CnH
If the Part Parameter Rcv PROGRAM CHANGE = OFF, that Part will not receive Pro-
gram Change Messages.
3. PITCH BEND
Status: EnH
If the Part Parameter Rcv PITCH BEND = OFF, that Part will not receive Pitch Bend Mes-
sages.
4. CONTROL CHANGE
Status: BnH
If the Part Parameter Rcv CONTROL CHANGE = OFF, that Part will not receive Control
Change Messages.
<Bank Select MSB/LSB> 00H/20H
Cntrl#
parameter
0
Bank Select MSB
32
Bank Select LSB
If the Part Parameter Rcv BANK SELECT = OFF, that Part will not receive Bank Select
Messages. A new bank selection will not become effective until the next Program Change
is received.
<Modulation> 01H
Cntrl#
parameter
1
Modulation
If the Part Parameter Rcv MODULATION = OFF, that Part will not receive Modulation
Messages.
<Breath Controller> 02H
Cntrl#
parameter
2
Breath Controller
<Foot Controller> 04H
Cntrl#
parameter
4
Foot Controller
<Portamento Time> 05H
Cntrl#
parameter
5
Portamento Time
When the Portamento parameter = ON, values will adjust the speed of pitch change.
A setting of 0= minimum portamento time, and 127 = maximum portamento time.
<Data Entry MSB/LSB> 06H/26H
Cntrl#
parameter
6
Data Entry MSB
38
Data Entry LSB
Messages which set the value for the parameter specified by RPN, NRPN.
<Main Volume> 07H
Cntrl#
parameter
7
Main Volume
If the Part Parameter Rcv MAIN VOLUME = OFF, that Part will not receive Main Volume
Messages.
<Pan> 0AH
Cntrl#
parameter
10
Panpot
If the Part Parameter Rcv PAN = OFF, that Part will not receive Pan Pot Messages.
1=Left, 127=Right; 0=Center
<Expression> 0BH
Cntrl#
parameter
11
Expression
If the Part Parameter Rcv EXPRESSION = OFF, that Part will not receive Expression
Messages.
<Control Change 13> 0DH
Cntrl#
parameter
13
Control Change13
<Hold1> 40H
Cntrl#
parameter
64
Hold1
If the Part Parameter Rcv HOLD 1 = OFF, that Part will not receive Hold 1 Messages.
<Portamento> 41H
Cntrl#
parameter
65
Portamento
If the Part Parameter Rcv PORTAMENTO = OFF, that Part will not receive Portamento
Messages. If the Portamento parameter = ON, values will adjust the speed of the porta-
mento. If the Mono mode is activated and Portamento = ON, the Single Trigger Mode will
be activated. If not, the Multi-Trigger Mode will be effective.
40
Data Range
33:Preset1/Preset2/Custom/Internal
81: VL-XG non alternative voice.
97: VL-XG alternative voice.
0 :Preset1
1 :Preset2
2 :Custom
3 :Internal
112...119: VL-XG Alternative or non alternative varia-
tion.
Data Range
0...127
Data Range
0...127
Data Range
0...127
Data Range
0...127
Data Range
0...127
0...127
Data Range
0...127
Data Range
0...127
Data Range
0...127
Data Range
0...127
Data Range
0...127 (0-63:Off, 64-127:On)
Data Range
0...127 (0-63:Off, 64-127:On)
<Soft Pedal> 43H
Cntrl#
parameter
Data Range
67
Soft Pedal
0...127 (0-63:Off, 64-127:On)
If the Part Parameter Rcv SOFT PEDAL = OFF, that Part will not receive Soft Pedal Mes-
sages. When the SOFT PEDAL is set "ON" the effect will take place from the next Key
On signal. Messages will control the Filter Cutoff Frequency. Depending upon the Voice,
the effect may or may not have an effect.
<Harmonic Content> 47H
Cntrl#
parameter
Data Range
71
Harmonic Content
0...127 (0:-64, 64:+0, 127:+63)
Messages which adjust the resonance set for each. Based on a standard of 64, these values
will be added to or subtracted from the Voice data. Depending on the Voice, the effective
range may be narrower.
<Release Time> 48H
Cntrl#
parameter
Data Range
72
Release Time
0...127 (0:-64, 64:+0, 127:+63)
Messages which adjust the envelope release time. Based on a standard of 64, values will
be added to or subtracted from the Voice data. Depending on the Voice, the effective range
may be narrower.
<Attack Time> 49H
Cntrl#
parameter
Data Range
73
Attack Time
0...127 (0:-64, 64:+0, 127:+63)
Messages which adjust the envelope attack time. Based on a standard of 64, values will be
added to or subtracted from the Voice data. Depending on the Voice, the effective range
may be narrower.
<Brightness> 4AH
Cntrl#
parameter
Data Range
74
Brightness
0...127 (0:-64, 64:+0, 127:+63)
Default:40H
Messages which adjust the filter cutoff frequency. Based on a standard of 64, values will
be added to or subtracted from the Voice data. Depending on the Voice, the effective range
may be narrower.
<Data Increment / Decrement> 60H/61H
Cntrl#
parameter
Data Range
96
Increment
0...127
97
Decrement
0...127
The data byte is ignored.
RPN messages which increase or decrease the MSB value of the parameter by 1.
<NRPN (Non-Registered Parameter Number) LSB/MSB> 62H/63H
Cntrl#
parameter
Data Range
98
NRPN LSB
0...127
99
NRPN MSB
0...127
If the Part Parameter Rcv NRPN = OFF, that Part will not receive NRPN Messages.
First send the NRPN MSB and NRPN LSB to specify the parameter which is to be con-
trolled. Then use the Data Entry to set the value of the specified parameter.
The following NRPN numbers can be received.
NRPNData-entry
MSB LSB MSB
parameter
01H
08H
mmH
Vibrato Rate
01H
09H
mmH
Vibrato Depth
01H
0AH mmH
Vibrato Delay
The Rate, Depth, and Delay Time for the Vibrato is controlled.
01H
20H
mmH
Filter Cutoff Frequency
01H
21H
mmH
Filter Resonance
01H
22H
mmH
Filter EG Depth
The Cut-off frequency, Resonance, and Envelope Depth for the Filter is controlled.
01H
30H
mmH
Bass
01H
31H
mmH
Treble
The Bass and Treble are controlled.
01H
63H
mmH
EG Attack Time
01H
64H
mmH
EG Decay Time
01H 66H mmH
EG Release
The Attack time, Decay time, and Release time for the Envelope are controlled. Based on
a standard of 64, values will be added to or subtracted from the Voice data. Depending on
the Voice, the effective range may be narrower.
<RPN (Registered Parameter Number) LSB/MSB> 64H/65H
Cntrl#
parameter
Data Range
100
RPN LSB
0...127
101
RPN MSB
0...127
If the Part Parameter Rcv RPN = OFF, that Part will not receive RPN Messages.
In correspondence to the following parameters.
Data Range
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)
mm:00H-40H-7FH
(-64-0-+63)