Sofar HYD 5KTL-3PH User Manual

Sofar HYD 5KTL-3PH User Manual

Energy storage integrated inverter
Hide thumbs Also See for HYD 5KTL-3PH:

Advertisement

User manual
Energy storage integrated inverter
Product Model: HYD 5K~20KTL-3PH
S h e n z h e n S O FA R S O L A R C o . , L t d .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYD 5KTL-3PH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sofar HYD 5KTL-3PH

  • Page 1 User manual Energy storage integrated inverter Product Model: HYD 5K~20KTL-3PH S h e n z h e n S O FA R S O L A R C o . , L t d .
  • Page 2: Table Of Contents

    User manual HYD 5-20KTL-3PH Content Preface......................II 1. Basic safety information..............- 1 - 1.1. Safety instructions..............- 1 - 1.2. Symbols and signs..............- 4 - 2. Product characteristics................ - 6 - 2.1. Product informations...............- 6 - 2.2. Size description............... - 7 - 2.3.
  • Page 3 SOFARSOLAR reserves the right of final interpretation.This manual is subject to change according to user’s or customer’s feedback.Please check our website at http://www.sofarsolar.com for latest version. Copyright © Shenzhen SOFAR SOLAR Co., Ltd.
  • Page 4: Preface

    You must understand these emphasized information to avoid the personal injury and property loss.Please read the following symbols used in this manual carefully. Copyright © Shenzhen SOFAR SOLAR Co., Ltd.
  • Page 5 Caution Attention indicates potential risks which, if not avoided, may lead to equipment fault or property damage. Attention Note provides tips that are valuable for the optimal operation of the product. Note Copyright © Shenzhen SOFAR SOLAR Co., Ltd.
  • Page 6: Basic Safety Information

    User manual HYD 5-20KTL-3PH 1. Basic safety information 1.1. Safety instructions Read and understand the instructions of this manual, and be familiar with relevant safety symbols in this chapter, then start to install and troubleshoot the equipment. According to the national and state requirements, before connecting to the electrical grid, you must get permission from the local electrical grid operation can only be performed by qualified electrical engineer.
  • Page 7 User manual HYD 5-20KTL-3PH etc.), and ensure that inverter is vertical placed. Choose a place suitable for installing electrical devices. And assure there is enough fire exit space, convenient for maintenance. Maintain proper ventilation to ensure enough air cycle to cool the inverter.
  • Page 8 User manual HYD 5-20KTL-3PH All installation accomplished only by professional electrical engineer! Must be trained; Completely read the manual operation and understand Warning relevant matter. Get permission from the local electrical gird operator, complete all electrical connections by professional electrical engineer, then connect inverter to electrical grid.
  • Page 9: Symbols And Signs

    User manual HYD 5-20KTL-3PH to electromagnetic noise of external system.Noise emission level: influence of electromagnetic emission upon environment. Electromagnetic radiation from inverter may be harmful to health! Please do not continue to stay around the inverter in less than 20 Danger cm when inverter is working.
  • Page 10 User manual HYD 5-20KTL-3PH This indicates the degree of protection of the equipment according to IEC standard 70-1 (EN 60529 June 1997). Positive pole and negative pole of the input voltage (DC). This side up, HYD 5-20KTL-3PH inverter must always be transported, handled and stored in such a way that the arrows always point upwards.
  • Page 11: Product Characteristics

    User manual HYD 5-20KTL-3PH 2. Product characteristics 2.1. Product informations HYD 5-20KTL-3PH inverter is a three-phase photovoltaic energy storage inverter integrating grid-connected photovoltaic inverter and battery energy storage. The HYD 5-20KTL-3PH inverter has a variety of built-in operating modes to suit the diverse user needs.
  • Page 12: Size Description

    User manual HYD 5-20KTL-3PH 2.2. Size description Fig. 2-2 Size chart Front view left view Bracket ① ② ③ 2.3. Function characteristics The HYD 5-20KTL-3PH energy storage inverters allow up to 10% overloading to maximize power output, and the Uninterruptible Power Supply (UPS) mode can support inductive loads such as air conditioners or refrigerators with an automatic switchover time of less than 20 milliseconds.
  • Page 13 User manual HYD 5-20KTL-3PH - 8 - Copyright © Shenzhen SOFARSOLAR Co., Ltd。...
  • Page 14: Installation

    User manual HYD 5-20KTL-3PH 3. Installation Installation notes Do NOT install the HYD 5-20KTL-3PH on flammable material. Do NOT install the HYD 5-20KTL-3PH in an area used to store Flammable or explosive material. Danger The enclosure and heat sink are very hot while the inverter is working, therefore do NOT install the HYD 5-20KTL-3PH in places where you might touch them inadvertently.
  • Page 15 User manual HYD 5-20KTL-3PH After unpacking the inverter, check whether deliverables are intact and complete. If any damage is found or any component is missing, contact the dealer. Table3-1 Components and mechanical parts that should be delivered Picture Description Quantity Inverter 1pcs Rear panel...
  • Page 16 User manual HYD 5-20KTL-3PH AC Grid connector 1pcs Load Output connector 1pcs Link port connector 1pcs 8 pin terminal Matching terminal resistance 1pcs (parallel system) DRMs connector 1pcs CT 6pin connector 1pcs Three phase electronic energy 1pcs meter Split Core Current 3pcs Transformer COM 16pin connector...
  • Page 17: Product Overview

    User manual HYD 5-20KTL-3PH 3.3. Product Overview HYD 5-20KTL-3PH inverter is 100% strictly inspected before package and delivery. It is forbidden to put the HYD 5-20KTL-3PH inverter upside down during delivery. CAUTION Please check the product package and fittings carefully before installation.
  • Page 18: Installation Environment

    User manual HYD 5-20KTL-3PH Removal tool Remove PV terminal Wire stripper Strip wire 4mm Allen Turn the screw to connect rear panel Wrench with inverter. Crimping tool Used to crimp power cables Multi-meter Used to check grounding Marker Used to mark signs Measuring tape Used to measure distances Used to ensure that the rear panel is...
  • Page 19: Determining The Installation Position

    User manual HYD 5-20KTL-3PH 3.6. Determining the Installation Position Determine an appropriate position for installing the HYD 5-20KTL-3PH inverter. Comply with the following requirements when determining the installation position. Fig. 3-3 Installation Position of HYD 5-20KTL-3PH inverter ① ② ③ ⑤...
  • Page 20: Moving The Hyd 5-20Ktl-3Ph

    User manual HYD 5-20KTL-3PH 3.7. Moving the HYD 5-20KTL-3PH Step 1 Open the packaging, insert hands into the slots on both sides of the inverter and hold the handles, as shown in Fig.3-4. Fig. 3-4 Moving the inverter ① ② Step 2 Lift the inverter from the packing case and move it to the installation position.
  • Page 21 User manual HYD 5-20KTL-3PH Fig. 3-5 Installing HYD 5-20KTL-3PH ① ② ③ ④ ⑤ - 16 - Copyright © Shenzhen SOFARSOLAR Co., Ltd。...
  • Page 22: Electrical Connections

    The connected PV modules must have an IEC 61730 Class A ratin Table 4-1 Relevant current parameters of each model IscPV(absolute Maximum output over current Model maximum) protection HYD 5KTL-3PH 8A*3 HYD 6KTL-3PH 15A/15A 10A*3 HYD 8KTL-3PH 13A*3 HYD 10KTL-3PH...
  • Page 23: Wire Instructions

    User manual HYD 5-20KTL-3PH NOTE:The DVC is the voltage of a circuit which occurs continuously between any two live part in the worst-case rated operating condition when used as intended. Table 4-2 The decisive voltage class(DVC) Interface PV input port DVCC Grid connection port DVCC...
  • Page 24: Connecting Pgnd Cables

    User manual HYD 5-20KTL-3PH Conductor Outdoor cross-sectional multi-core area:10mm ~ copper cable 16mm 4.2. Connecting PGND Cables Connect the inverter to the grounding electrode using protection ground (PGND) cables for grounding purpose. The inverter is transformer-less, requires the positive pole and negative pole of the PV array are NOT grounded.
  • Page 25: Battery Connection & Pv Connection

    User manual HYD 5-20KTL-3PH 1. M5 screw 2. OT Terminal 3. Tapped hole ③ 4.3. Battery Connection & PV Connection The connection mode of Battery connection and PV connection is the same, only the terminal specifications are different. Please correctly correspond when inserting the terminal into the machine end.
  • Page 26: Load Connection

    User manual HYD 5-20KTL-3PH removal wrench into the bayonet and press the wrench with an appropriate strength, as shown in Fig.4-2 ⑦ Before removing the positive and negative connectors, ensure that the DC SWITCH is OFF. Fig.4-2 Connect Battery&PV 1: Positive metal contact 3: Positive connector 2: Negative metal contact 4: Negative connector...
  • Page 27: Grid Connection

    User manual HYD 5-20KTL-3PH Step 3 Connect the wire to the terminal according to the identification on the terminal, as shown in Fig.4-3 ③④ Step 4 Connect the terminal to the machine port and rotate the clamp clockwise. Fig.4-3 Load connection A:30~50mm B:3~5mm ①...
  • Page 28: External Communication Interface

    User manual HYD 5-20KTL-3PH A:30~50mm B:3~5mm ① ② ③ ④ ⑤ ⑥ 4.6. External communication interface 4.6.1 USB/WIFI communication interface Fig.4-5 USB/WIFI communication interface ③ ① ② Table 4-4 Interface description Definition Function Note GND.S USB power - The USB power supply is USB data + 5V/1A;...
  • Page 29 User manual HYD 5-20KTL-3PH 1.White and orange 2.Orange 3.White and green 4.Blue 5.White and blue 6.Green 7.White and brown 8.Brown ③ ① ② ④ ⑥ ⑤ Procedure: Step 1 Press the wire terminals in color sequence. Step 2 Route Cable terminal through the cable gland, Insert the communication cable into the RJ45 connector.
  • Page 30 User manual HYD 5-20KTL-3PH Table 4-6 Function description of the terminal Pin NO. Pin name Description Connected to (RRCR) Relay contact 1 input K1 - Relay 1 output Relay contact 2 input K2 - Relay 2 output Relay contact 3 input K3 - Relay 3 output Relay contact 4 input K4 - Relay 4 output...
  • Page 31 User manual HYD 5-20KTL-3PH Relay contact 1 input K1 - Relay 1 output Not Connected Not Connected Not Connected Not Connected Not Connected Not Connected Not Connected Not Connected K1 - Relay 1 output Not Connected Not Connected Not Connected Not Connected Table 4-9 The inverter is preconfigured to the following RRCR power levels,close is 1, open is 0 Active Power...
  • Page 32 User manual HYD 5-20KTL-3PH Table 4-10 Interface description Definition Function Note RS485A1-1 RS485 differential signal + RS485A1-2 RS485 differential signal + Wired monitoring or inverter RS485B1-1 RS485 differential signal – cascade monitoring RS485B1-2 RS485 differential signal – RS485A2 RS485 differential signal + Communicate with electricity RS485B2 RS485 differential signal -...
  • Page 33 User manual HYD 5-20KTL-3PH ① ② ③ ④ 4.6.4 Link Port 0&1-Cascade communication interface Fig.4-12 Link Port ① ② ③ - 28 - Copyright © Shenzhen SOFARSOLAR Co., Ltd。...
  • Page 34 User manual HYD 5-20KTL-3PH When using the parallel system, the inverter settings and notes please refer to this manual<6.3.2 Advanced setting→6.Parallel setting>. Note(AC LOAD is also parallel for parallel machines): The first and last two inverters need to be connected with 8Pin connection terminals.
  • Page 35 User manual HYD 5-20KTL-3PH 4.6.5 CT-External current sensor interface Table 4-12 Interface description Definition Function Note The current sensor outputs a Ict_R- negative electrode Used to connect R phase current sensor of power grid The current sensor outputs a Ict_R+ positive electrode The current sensor outputs a Ict_S-...
  • Page 36 User manual HYD 5-20KTL-3PH Fig. 4-15 Electrical connections (Plan A:CT) - 31 - Copyright © Shenzhen SOFARSOLAR Co., Ltd。...
  • Page 37 User manual HYD 5-20KTL-3PH Fig. 4-16 Electrical connections (Plan B:Meter +CT ) - 32 - Copyright © Shenzhen SOFARSOLAR Co., Ltd。...
  • Page 38: Communication Method

    User manual HYD 5-20KTL-3PH 4.7. Communication method HYD 5-20KTL-3PH offer RS485 (standard) and WiFi/GPRS (optional) communication modes: A. Single inverter communication : 1. RS485 Refer to the figure shown below, connect the RS485+ and RS485- of the inverter to the TX+ and TX- of the RS485→ USB adapter, and connect the USB port of the adapter to the computer.(NOTE :...
  • Page 39 User manual HYD 5-20KTL-3PH Web: https://home.solarmanpv.com (Recommended browser: Chrome58、 Firefox49、 IE9 and above version). APP:Android: Go to Android Market and search “SolarMAN”. IOS: Go to App Store and search “SolarMAN”. SolarMAN-3.0-Web User Manual,Please visit the https://doc.solarmanpv.com/web/#/7. SolarMAN-App User Manual,Please visit the https://doc.solarmanpv.com/web/#/14. B.
  • Page 40: Buttons And Indicator Lights

    User manual HYD 5-20KTL-3PH 5. Buttons and indicator lights Fig.5-1 Buttons and indicator lights 5.1. Buttons press “Back” to the previous screen or enter the main interface.  press “Up” to the upper menu option or value plus 1.  press “Down”...
  • Page 41: Operation

    User manual HYD 5-20KTL-3PH 6. Operation 6.1. Double Check Please double check the following before operation. Inverter is firmly fastened to the mounting bracket on the wall. PV+/PV- wires are firmly connected, polarity and voltage are correct. BAT+/BAT- wires are firmly connected, polarity and voltage are correct. DC isolator is correctly connected between battery &...
  • Page 42 User manual HYD 5-20KTL-3PH Table 6- 1 Set the parameters Parameter Note 1.OSD Language Option The default English. If you are connected to the host computer such 2.System time setting as collector or mobile phone APP, the time and confirmation should have been calibrated to the local time.
  • Page 43: Menu

    User manual HYD 5-20KTL-3PH example).Start with battery 1 and work your way up to battery n. Battery Type Type of band Lead acid or no protocol communication protocol type 1.Battery Address 1.Battery Capacity 2.Battery Charge Current 2.Battery Nominal Voltage Limit 3.Battery Discharge 3.Battery Cell Type Current Limit...
  • Page 44 User manual HYD 5-20KTL-3PH AC Current R....**.**A AC Current S....**.**A AC Current T....**.**A Frequency....**.**Hz Down ↓ Battery Information (1) Batt1 (V)......****.*V Batt1 Curr......**.**A Batt1 Power....**.*KW Batt1 Temp......*℃ Batt1 SOC......**% Batt1 SOH......**% Batt1 Cycles......*T Down↓ Battery Information (2) Batt2 (V)......****.*V Batt2 Curr......**.**A Batt2 Power....**.*KW Batt2 Temp......*℃...
  • Page 45 User manual HYD 5-20KTL-3PH 6.3.1 System setting 1. System Setting 1.Language Settings 2.Time 3.Safety Param. 4.Energy Storage Mode 5.Auto Test(Only for Italy) 6.Input Channel Config 7.EPS Mode 8.Communication Addr. 1. Language Settings Used to set the menu display language. 1.Language Settings 1.中文...
  • Page 46 User manual HYD 5-20KTL-3PH If the battery is full(or already at Max generation < LOAD Charge Power), excess power will be consumption, it will discharge the exported to the grid. battery to supply power to load. If PV generation + Battery < LOAD consumption, inverter will import power from the grid.
  • Page 47 DisCharge End 16 h 00m DisCharge Power 02500 W Passive Mode For more detailed information, please ask representative of SOFAR to get a copy of passive mode communication protocol. 5. Auto Test (ONLY for Italian Market) 5.Auto Test 1.Autotest Fast 2.Autotest STD...
  • Page 48 User manual HYD 5-20KTL-3PH ↓ Wait Test 59.S2 OK! ↓ Wait Testing 27.S1... ↓ Wait Test 27.S1 OK! ↓ Wait Testing 27.S2... ↓ Wait Test 27.S2 OK! ↓ Wait Testing 81>S1... ↓ Wait Test 81>S1 OK! ↓ Wait Testing 81>S2… ↓...
  • Page 49 User manual HYD 5-20KTL-3PH ↓ Press “Down” 81>.S1 threshold 50.5Hz 100ms ↓ Press “Down” 81>.S1 49.9Hz 103ms ↓ Press “Down” 81>.S2 threshold 51.5Hz 100ms ↓ Press “Down” 81>.S2 49.9Hz 107ms ↓ Press “Down” 81<.S1 threshold 49.5Hz 100ms ↓ Press “Down” 81<.S1 50.0Hz 105ms ↓...
  • Page 50 User manual HYD 5-20KTL-3PH If PV generation > LOAD consumption generation LOAD (ΔP > 100W), inverter will charge battery. consumption, inverter wont’ charge or discharge battery. If PV generation < LOAD consumption If PV generation is normal,but LOAD (ΔP > 100W), inverter will discharge consumption=0, the surplus power will be battery.
  • Page 51 1.Battery Parameter 1.Battery Type 5.Max Charge (A) 2.Battery Capacity 6.Max Discharge (A) 3.Nominol Bat Voltage 7.*Discharg Depth 4.Battery Cell Type 8.Save B.PYLON/SOFAR 1.Battery Parameter 1.Battery Type 4.Max Discharge (A) 2.Battery Address 5.Discharg Depth 3.Max Charge (A) 6.Save Depth of Discharge For example: if Discharge Depth = 50% &...
  • Page 52 User manual HYD 5-20KTL-3PH 3.IV Curve Scan Enable 1.Scan Control Disable 2.Scan Period ***min 3.Force Scan Logic interface Control Enable or disable logical interfaces. Please refer to this manual 4.6.2, inverter logic interface connection for details. 4.Logic interface Control Enable Disable Factory Reset 1.Clear Energy Data...
  • Page 53 User manual HYD 5-20KTL-3PH 8. CT Calibration To calibrate the direction and phase of the CT, the battery should be charged or discharged when using this function. Calibrating Sucess/Fault 8.CT Calibration Check if the battery is charging or discharging when calibration fails。 6.3.3 Energy Statistic 3.Energy Statistic Today...
  • Page 54 User manual HYD 5-20KTL-3PH 2.Battery Info 3.Safety Param. 1.Inverter Info Inverter Info (1) Product SN Software Version Main DSP Software Version Slave DSP Software Version Down↓ Inverter Info (2) Hardware Version Power Level Country Inverter Info (3) Down↓ Input Channel1 Input Channel2 Input Channel3 Input Channel4...
  • Page 55 Step 1 Insert the usb flash drive into the compute. Step 2 SOFAR SOLAR will send the Software code to the user who needs to update. After user receive the file,please decompressing file and cover the original file in usb flash drive.
  • Page 56 User manual HYD 5-20KTL-3PH Step 4 Insert the usb flash drive into the USB/Wifi interface. Step 5 Then turn on DC switch. Step 6 6.Software Update Input password OK Input 0715 Start Update Updating DSP1 Updating DSP2 Updating ARM Step 7 If the following errors occur, please upgrade again.If this continues many times, contact technical support for help.
  • Page 57: Troubleshooting

    User manual HYD 5-20KTL-3PH 7. Troubleshooting This section contains information and procedures for solving possible problems with the inverter. This section help users to identify the inverter fault. Please read the  following procedures carefully: Check the warning, fault messages or fault codes shown on the inverter ...
  • Page 58 User manual HYD 5-20KTL-3PH Code Name Description Solution The grid voltage is too If the alarm occurs occasionally, the ID001 GridOVP high possible cause is that the electric grid is abnormal occasionally. Inverter will The grid voltage is too ID002 GridUVP automatically return to normal operating status when the electric grid’s back to...
  • Page 59 User manual HYD 5-20KTL-3PH Inverter voltage ID012 InvOVP overvoltage Power grid current ID017 HwADFaultIGrid sampling error Wrong sampling of dc ID018 HwADFaultDCI component grid current HwADFaultVGri Power grid voltage ID019 d(DC) sampling error (DC) HwADFaultVGri Power grid voltage ID020 d(AC) sampling error (AC) GFCIDeviceFault Leakage...
  • Page 60 User manual HYD 5-20KTL-3PH ID041 RelayFail Relay detection failure insulation Check the insulation resistance between the impedance photovoltaic array and ground (ground), if ID042 IsoFault there is a short circuit, the fault should be repaired in time. ID043 PEConnectFault Ground fault Check ac output PE wire for grounding.
  • Page 61 User manual HYD 5-20KTL-3PH Module 2 temperature ID060 TempFault_Inv2 protection Module 3 temperature ID061 TempFault_Inv3 protection VbusRmsUnbala Unbalanced bus voltage Internal faults of inverter, switch OFF ID065 inverter, wait for 5 minutes, then switch ON inverter. Check whether the problem is The transient value of VbusInstantUnba solved.
  • Page 62 User manual HYD 5-20KTL-3PH software protection overcurrent ID082 DciOCP protection Output instantaneous ID083 SwOCPInstant current protection SwBuckBoostOC BuckBoost software ID084 flow Output effective value ID085 SwAcRmsOCP current protection overcurrent ID086 SwPvOCPInstant software protection PV flows in uneven ID087 IpvUnbalance parallel Unbalanced output ID088...
  • Page 63 User manual HYD 5-20KTL-3PH Please ensure that the inverter is installed in a cool/well ventilated place. Ensure the inverter is installed vertically and the ambient temperature is below the inverter temperature limit. AC frequency is too Please make sure the grid frequency and ID114 FreqDerating high...
  • Page 64 User manual HYD 5-20KTL-3PH failure Permanent failure of unrecoverIacUnb ID135 unbalanced output alance current unrecoverPvConf Input mode setting error Check input mode ID137 igError permanent failure (parallel/independent mode) Settings for the inverter. If not, change the PV input mode. unrecoverPVOCP Input overcurrent ID138...
  • Page 65 User manual HYD 5-20KTL-3PH versions upgrades. Communication failure Make sure your battery is compatible with of lithium battery the inverter. BMSCommunica ID157 CAN communication is recommended. tonFault Check the communication line or port of the battery and inverter for faults. Force shutdown The inverter performed...
  • Page 66 User manual HYD 5-20KTL-3PH alarm inverter and lithium battery, and wait 5 minutes to open inverter and lithium battery. BMS under-voltage ID178 BMS UVP Check that the problem is resolved. If not, alarm please contact technical support. BMS high temperature ID179 BMS OTP warning...
  • Page 67: Technical Data

    User manual HYD 5-20KTL-3PH 8. Technical Data Battery Parameters 5KTL- Datasheet 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH Battery type Li-lon No. of battery input Battery voltage 180V-800V range Battery voltage 200-800 240-800 320-800 200-800 300-800 400-800 range for full load(V) Nominal.
  • Page 68 User manual HYD 5-20KTL-3PH PV String Input Data Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH 7500 9000 12000 15000 22500 30000 Recommended (6000/ (6600/ (6600/ (7500/ (11250/ (15000/ Max.PV power 6000) 6600) 6600) 7500) 11250) 15000) Max DC voltage 1000V Start-up 200V...
  • Page 69 User manual HYD 5-20KTL-3PH AC Output Data (ON-Grid ) Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH Nominal AC 5000 6000 8000 10000 15000 20000 power(W) Max. AC power output to utility 5500 6600 8800 11000 16500 22000 grid(VA) Max.
  • Page 70 User manual HYD 5-20KTL-3PH AC Output Data (Off-Grid ) Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH Nominal output 5000 6000 8000 10000 15000 20000 power(W) Max. output 5500 6600 8800 11000 16500 22000 power(VA) Peak output power, 10000V 12000V 16000V...
  • Page 71 User manual HYD 5-20KTL-3PH Efficiency And Protection Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH MPPT efficiency 99.9% Euro efficiency 97.5% 97.5% 97.5% 97.7% 97.7% 97.7% Max. efficiency 98.0% 98.0% 98.0% 98.2% 98.2% 98.2% Max. battery charge/discharge 97.6% 97.6% 97.6% 97.8%...
  • Page 72 User manual HYD 5-20KTL-3PH General Data Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH Dimension 571.4mm*515mm*264.1mm Weight 33kg 37kg Inverter topology Transformerless Standby self <10W consumption Operating -30℃~60℃ temperature range Relative humidity 0~100% Noise <45dB Operating altitude <4000m Cooling Natural Forced airflow...
  • Page 73 User manual HYD 5-20KTL-3PH Feature And Standard Datasheet 5KTL- 6KTL- 8KTL- 10KTL 15KTL 20KTL -3PH -3PH -3PH DC terminal Grid AC terminal 5P Connector Back-up AC 5P Connector terminal Display LCD Display Monitoring Bluetooth / RS485 / WIFI / GPRS (optional) interfaces Parallel operation Standard warranty...
  • Page 74: Quality Assurance

    User manual HYD 5-20KTL-3PH 9. Quality Assurance Standard warranty period The standard warranty period of inverter is 60 months (5 years). There are two calculation methods for the warranty period: 1. Purchase invoice provided by the customer: the first flight provides a standard warranty period of 60 months (5 years) from the invoice date;...
  • Page 75 User manual HYD 5-20KTL-3PH Without the consent of our company to change equipment or replace parts; Use unqualified materials to support our company's products, resulting in product failure; Technicians of non-company modify or attempt to repair and erase the product serial number or silk screen; Incorrect installation, debugging and use methods;...
  • Page 76 Product Name: Energy storage integrated inverter ADD: 401, Building 4, AnTongDa Industrial Park, District 68,XingDong Community, XinAn Street, BaoAn District, Shenzhen, GuangDong.P.R. China Email: service@sofarsolar.com Tel: 0510-6690 2300 Web: www.sofarsolar.com...