Dimplex M Flex 0609 Installation And Operating Instruction page 27

Air-to-water heat pump
Table of Contents

Advertisement

Air-to-water heat pump M Flex
Type and order code
5
Electrical connection
5.1
Supply voltage / fusing / RCD type
5.2
Control voltage / fusing via WPM
5.3
Degree of protection according to EN 60 529 indoors / outdoors
5.4
Starting current limiter
5.5
Starting current
5.6
Nominal power consumption A2/W35 / max. consumption
5.7
Nominal current A2/W35 / cos φ
5.8
Power consumption of fan
6
Complies with the European safety regulations
7
Additional model features
7.1
Type of defrosting
7.2
Condensate tray frost protection /
Water in device is protected from freezing
7.3
Max. operating overpressure (heat sink)
2 6
8
Heat output / COP
8.1
Heat output / COP
1. For air temperatures between -22 °C and -5 °C, flow temperature increasing from 45 °C to 60 °C
2. These data indicate the size and capacity of the system according to EN 14511.
For an analysis of the economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and
regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers.
Information on maintenance, commissioning and operation can be found in the respective sections of the installation and operating instructions.
The specified values, e.g. A2 / W35, have the following meaning: outside air temperature 2 °C and heating water flow temperature 35 °C.
3. The heat output and COP is reduced by approx. 5 % in lower operation.
4. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the instal-
lation location.
5. Note that additional space is required for pipe connections, operation and maintenance.
6. Indoor and outdoor component must be connected with two refrigerant pipes (high and low pressure). The length information refers to one section.
The specified technical data applies to a refrigerant pipe length of 3m per section (minimum permissible).
For longer refrigerant pipes, the heat output is reduced by 2 % and the COP is reduced by 3 % per meter section length.
The maximum permissible section length (without adjusting the refrigerant quantity) is 7 m. The refrigerant quantity pre-filled at the factory is sufficient
up to this length.
From a single pipe length of 7 m, the refrigerant quantity must be adjusted. The maximum permissible length of the pipe with refrigerant top-up is
10 m.
The specified directives for routing refrigerant pipes and topping up refrigerant can be found in the installation and operating instructions.
7. The heat circulating pump and the heat pump controller must always be ready for operation.
www.glendimplex.de
Compressor
Pipe heater
2
kW
A / --
7
bar
with A-7 / W35
kW / --
with A2 / W35
kW / --
with A7 / W35
kW / --
DOK4x HOIAO FxDEN · FD 0001
M Flex 0609
1~/N/PE 230 V (50 Hz) /
1~/N/PE 230 V (50 Hz) /
C20A / B
1~/N/PE 230 V (50 Hz) /
1~/N/PE 230 V (50 Hz) /
1~
B32A / A
3~/N/PE 400 V (50 Hz) /
3~
B10A / A
1~/N/PE 230 V (50 Hz) /
1~/N/PE 230 V (50 Hz) /
C13A
IP 21 / IP 24
Inverter
A
Inverter
1.1 x 2.9
5.2 x 0.99
W
up to 200
see CE declaration of
conformity
Reverse circulation
yes
2.5
EN 14511
6.0 x 3.03
4.2 x 4.16
4.7 x 4.76
M Flex 0916M
M Flex 0916
3~/N/PE 400 V (50 Hz) /
C25A / B
C10A / B
B32A / A
3~/N/PE 400 V (50 Hz) /
B10A / A
1~/N/PE 230 V (50 Hz) /
C13A
IP 21 / IP 24
IP21 / IP24
Inverter
Inverter
Inverter
Inverter
1.55 x 4.4
1.55 x 4.9
6.8 x 0.99
2.3 x 0.99
up to 200
up to 200
see CE declaration of
see CE declaration of
conformity
conformity
Reverse circulation
Reverse circulation
yes
2.5
EN 14511
EN 14511
9.4 x 3.03
9.4 x 3.03
6.5 x 4.33
6.5 x 4.33
6.9 x 4.96
6.9 x 4.96
English
C13A
yes
2.5
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

M flex 0916M flex 0916m09choiaof616ihoiaof616choiaof6